Страница 1
Issued by Canon Europa N.V.
Model : Finisher-D1 No.: Acc-150 Rev. 1
Finisher-E1 (FF-T01-W-000058-02)
DATE: 10.09.99
Location : INTRODUCING A NEW TOOL
Subject : DOWNLOADING USING FINISHER DOWNLOADER PCB
Reason : This bulletin communicates how to download from a computer (PC) through a downloader PCB as a
means of upgrading the ROM of a finisher.
Details : 1. Applicable Models
May be used for the following two models:
Finisher-E1 Finisher-D1
Figure 1-2 Figure 1-1
– 1 / 9 –
Страница 2
2. Components of the Downloader PCB (FY8-2034-000)
[5 ] [8 ] [1 ] [2 ] [3 ] [4 ] [7 ] [6 ]
Figure 2-1
Names and Functions of the Parts
Ref. Name Remarks
[1] START/STOP button Press it to start/stop downloading.
[2] LOAD LED Remains on when downloading is ready.
[3] Model indicator LED Remains on when the Finisher-D1 is connected.
[4] Power indicator LED Remains on when the downloader PCB is supplied
with power by the finisher.
[5] RS-232C cable Use it to connect the downloader PCB to a
(straight, full connection; 9-pin) computer. Be sure to make a connection so that the
ferrite core of the cable is on the computer side.
[6] Cable A (9-pin; about 70 cm in length) Use it to connect the PCB to the Finisher-D1.
[7] Cable B (7-pin; about 50 cm in length) Use it to connect the PCB to the Finisher-E1.
[8] RS-232C connector Use it to connect the RS-232C cable to the PCB.
Table 2-1
3. Related Tool
For downloading, you must obtain the following item:
¥ Computer (PC)
Requirements.
OS Windows95 or 98
Processor Pentium 75 MHz or better
Available memory 16 MB or more
External connection connector RS-232C connector (9-pin, male)
Table 3-1
– 2 / 9 –
Страница 3
4. Downloading Procedure
A. Connecting to the Finisher
1) Turn off the copier.
2) Detach the PCB cover of the finisher (1 screw for the Finisher-D1) or the rear cover (2 screws for
the Finisher-E1).
Screw
Rear cover
Screws
PCB cover
Finisher-D1 Finisher-E1
Figure 4-1 Figure 4-2
3) Connect the cable A to J130 of the finisher controller PCB (for the Finisher-D1). Or, connect the
cable B to J13 of the finisher controller PCB (for the Finisher-E1).
J130
9-pin
J13
Cable A
7-pin
Cable B
Finisher-D1 Finisher-E1
Figure 4-3 Figure 4-4
– 3 / 9 –
Страница 4
4) For the Finisher-D1, shift bit 6 of the DIP switch SW107 to ON.
SW107
Figure 4-5
4) Connect the RS-232C cable to the PCB and the RS-232C connector of the computer.
5) Make sure that the ferrite core of the RS-232C cable is on the computer side.
5) Turn on the copier.
6) The power indicator LED on the PCB turns on. If the connection is to a Finisher-D1, the model
indicator LED will also turn on.
B. Adding ROM Data
1) Put the ROM data you want into the folder "C\ServTool\NewROM."
2) Start the service support tool.
C:\ ProgramFiles \ Service Support Tool \ bpchost.exe
3) Select "Controlling Data."
Figure 4-5
4-6
– 4 / 9 –
Страница 5
4) Select "Adding ROM Data."
Figure 4-6
4-5
5) Select "Register."
The data will be stored in hard disk. The data found in the folder "NewROM" will be deleted.
Figure 4-7
4-8
– 5 / 9 –
Страница 6
C. Downloading
Caution: In the case of the Finisher-D1, ‘E500’ or ‘E501’ can occur during downloading
operation. Such, however, will not affect the results of the work.
1) Start service support tool.
C: \ ProgramFiles \ ServiceSupportTool \ bpchost.exe
2) Select "Downloading/Uploading."
Figure 4-8
4-9
3) Press the START/STOP button.
The LOAD LED will turn on.
4) Select the model for downloading.
Select the name of the model to highlight, and press the Connect button.
Figure 4-9
4-10
– 6 / 9 –
Страница 7
5) According to the instructions on the screen, make preparations for downloading.
Press the OK button on the screen to move to the next screen.
Figure 4-10
4-11
6) Select the version of the ROM you want to download.
Figure 4-11
4-12
– 7 / 9 –
Страница 8
7) Press the Connect button so that the computer and the PCB will download the program.
Figure 4-12
4-13
8) When downloading has ended normally, press the OK button.
Figure 4-13
4-14
– 8 / 9 –
Страница 9
9) Follow the instructions on the screen to end the work.
Figure 4-14
4-15
5. Disconnecting
1) Press the START/STOP button.
The LOAD LED will turn off.
2) Disconnect the cable A or B from the finisher.
3) Turn off the host copier.
For the Finisher-D1, shift bit 6 of SW107 to OFF.
4) Mount the PCB cover of the finisher (for the Finisher-D1) or the rear cover (for the Finisher-E1).
6. Service Parts
FIGURE
& Part number Q’ty Description Remarks
KEY No.
– FY9-2034-000 1 DOWN LOADER PCB ASSEMBLY
– 9 / 9 –