Технический бюллетень. Canon GP405/335. Документ GP405-008. Тема: PREVENTION OF JAM 0131.
Canon · Технический бюллетень · 3 стр. · PDF
Ниже приведён текст исходного документа. Схемы, иллюстрации и исходное расположение таблиц сохранены в файле для скачивания.
Текст документа
Страница 1
Issued by Canon Europa N.V.
Model : GP405/335 No.: GP405-008
(FF-T01-J7-000023-01)
DATE: 10.08.99
Location : REGISTRATION FRONT GUIDE ASSEMBLY
Subject : PREVENTION OF JAM 0131
Reason : To communicate changes that have been made to the registration front guide assembly in order to
reduce the number of 0131 jams.
Details : <Symptom>
There are cases where jam 0131 (stationary jam) results due to the paper remaining in the registration
front guide assembly.
<Cause>
The mylar (FB4-3311-000) stuck to the registration front guide assembly becomes charged
(depending on the environmental conditions and paper types) by the paper going past the mylar,
causing the copy paper to stick to the mylar.
<Factory measure>
The following changes were made to the mylar stuck to the registration front guide assembly:
• Change to a material with high conductivity (from Corton to Tufflite)
• Change in the shape of the mylar (see Fig. 1 for the tab shapes circled) for sticking the mylar and the
sensor plate together to the registration front guide assembly and for reliably grounding the charge built
on the mylar surface.
Sensor plate
New mylar
FB4-3311-020 Fig. 1 Registration front guide assembly
– 1 / 3 –
Страница 2
Servicing : It is necessary to remove and replace the registration front guide assembly in order to take the same
measures in the field (as taken at the factory). Since the work will take approximately 20 minutes,
even by persons who are accustomed to removing and replacing the registration front guide assembly,
the procedure (different from the procedure for the factory) for doing the work in the field has been
established as follows:
Things to prepare: Mylar for field use (not assigned as a service part but supplied free to the sales
companies)
1) Open the right door of the main unit.
2) Stick the new mylar over the old mylar stuck to the registration front guide assembly (see Fig. 2 for
sticking the mylar to the specific position).
Precautions to take in sticking the mylar:
In the figure below, the solid line B shown for the field use mylar and the solid line A on the
registration guide assembly are references for lapping the new mylar over the old mylar.
Stick the field use mylar in such a way that their tab sections are positioned and sandwiched
by the sensor plate and the registration front guide assembly.
3) Since the multi-paper detection sensor and the right door open/close detection sensor will not
function normally if the sensor plate is attached at an angle, check the function of these sensors
upon completing the servicing work.
Solid line A
Solid line B
Mylar for field use
Fig. 2 Registration front guide assembly
Service Parts :
GP405
Inter- P.C.
No. Description Part number Q’ty change- — — — — — — — — —
ability
1 Old SHEET, LOWER GUIDE FB4-3311-000 1→0 341-15B
No Yes
NewSHEET, LOWER GUIDE FB4-3311-020 0→1
2 Old GUIDE, REGISTRATION, UPPER FF5-6996-000 1→0 341-15
No Yes
NewGUIDE, REGISTRATION, UPPER FF5-6996-020 0→1
3 Old REGIST. FRONT GUIDE ASSEMBLY FG6-0591-000 1→0 341 No Yes
NewREGIST. FRONT GUIDE ASSEMBLY FG6-0591-040 0→1
– 2 / 3 –
Страница 3
Affected machines:
GP405 FRN SNY01241 and later
GER TNY00594 and later
UK QNY01623 and later
AMS UNY03080 and later
ITA PNY00411 and later
GP335 FRN SNZ01151 and later
GER TNZ00881 and later
UK QNZ01818 and later
AMS UNZ03686 and later
ITA PNZ00411 and later
– 3 / 3 –