Страница 1

COPIER Service Bulletin

Issued by Canon Europa N.V.

Model : GP605 Series No.: GP605-015
(FF-T01-K1-000031-01)
DATE: 10.09.99

Location : IMAGE PROCESSER PCB ASSEMBLY/MFC PCB ASSEMBLY

Subject : UPGRADING PROM PROGRAM OF IMAGE PROCESSER PCB ASSEMBLY/MFC PCB
ASSEMBLY (IP VER. 20.11/MFC VER. 20.05, IP VER. 21.01/MFC VER. 21.02)

Reason : To communicate that the image processor PCB / MFC PCB ROM program has been upgraded for full
system finisher compatibility and to correct a malfunction.

[History of ROM modifications]

Service Bulletin Ver. No. Description
IP MFC
Ver. 21.01 Ver. 21.02 IP: Correction of malfunction
MFC: Change to printer compatibility
specifications
Ver. 20.11 Ver. 20.05 Full system finisher compatibility
GP605-010 Rev. 1 Ver. 10.12 Ver. 10.10 IP : For compatibility with LIPS IV
GP605-003 Rev. 1 Ver. 7.03 Ver. 7.03 IP : For compatibility with PDL kanji
MFC : Correction of faults
_____ Ver. 4.06 Ver. 6.02 MFC : Correction of faults
Ver. 5.01 Early stage production version

– 1 / 4 –

Страница 2

GP605-015

Details : <Modifications in IP Ver. 20.11 >

No. Item Description
1 Prevention of cleaner lock In order to prevent locking of the cleaner due to toner blocking, the speed
of the fixing feeder fan was changed to full speed.
Also, in order to respond to complaints on noise from users, a mode was
added to switch the fan speed to full speed only in high humidity
environments or when room temperature is 29°C or higher, and to half
speed in normal environments.
Service mode : COPIER/OPTION/BODY/FX-FANSW
0: After printing, controls the fixing fan at full speed
1: Switches to full speed only in high humidity environments or when
room temperature is 29°C or higher, and to half speed in normal
environments
2 Changed specifications Changed output so that tray A output is output from tray B if 1 page data is
regarding sort/non-sort flushed out of the printer by sort, because of requests from the field. Also,
when auto-sort is OFF compatibility with reverse-direction printing by way of the copy paper
sort/non-sort with an attached header.
Sort: Output to tray B with total face-down delivery
Non-sort: Output to tray A with face-up delivery with one document, and
face-down delivery with multiple documents
3 Dealing with E110 in high A problem was corrected in which the polygon motor was switched
altitude (low atmospheric between full and half speed in quiet mode but where rotation would not
pressure) environment drop due to low atmospheric pressure.

<Modifications in MFC Ver. 20.05 >
No. Item Description
1 Addition of system Addition of system supervisor password clear process
supervisor password clear Service mode : COPIER/FUNCTION/CLEAR/PWD-CLR
process
2 Deletion of master In order to set apart the system supervisor, the only password able to be
password entered other than regular passwords is the system supervisor password, so
the master password was removed.
3 Setting for time period in Changed so that the time period for automatic deletion of mail boxes can be
which to automatically set without the imposition of set period of time.
delete mail boxes Service mode : COPIER/OPTION/MB-T-LIM
4 Prevention of cleaner lock In order to prevent locking of the cleaner due to toner blocking, the speed
of the fixing feeder fan was changed to full speed.
Also, in order to respond to complaints on noise from users, a mode was
added to switch the fan speed to full speed only in high humidity
environments or when room temperature is 29°C or higher, and to half
speed in normal environments.
Service mode : COPIER/OPTION/BODY/FX-FANSW
0: After printing, controls the fixing fan at full speed
1: Switches to full speed only in high humidity environments or when
room temperature is 29°C or higher, and to half speed in normal
environments
5 Correction of malfunction 1) On the sort screen, even if stapling was de-selected, automatic detection
in control panel key of document orientation was not cleared. This problem was corrected.
operation 2) In the mailbox password setting screen, “Please enter password” was
corrected to “Please set password.”

– 2 / 4 –

Страница 3

GP605-015

<Modifications in IP Ver. 21.01 >
No. Item Description
1 Correction of If booklet printing was done with Paper Size=A4/LTR from the
malfunction when full PCL driver with a combination of the printer board and the
system finisher full system finisher, A4/LTR-H was fed and saddle stitching
connected not performed. This problem was corrected.

<Modifications in MFC Ver. 21.02 >
No. Item Description
1 Change the method of 1) Addition of process to distinguish copying machine and printer models.
operation for service 2) Correction made so that in the LCD check, the function is stopped by
mode control panel the clear key, not by the stop key according to the way this is done for
check the printer models.
3) Correction made so that, in the LED check, the order of the LED
flashing on and off is done in the same sequence as the flashing on and
off of the printer model’s hard key.

Service Parts :

Inter- P.C.
No. Description Part number Q’ty change- — — — — — — — — —
ability
1 Old IMAGE PROCESSOR PCB FG6-1911-000 1→0 905-1
No Yes
New IMAGE PROCESSOR PCB FG6-1911-090 0→1
2 Old DIMM ASS’Y MBM29F080-90PFTN FG6-1922-000 1→0 905-1
No Yes
New DIMM ASS’Y MBM29F080-90PFTN FG6-1922-210 0→1
3 Old IMAGE PROCESSOR PCB FG6-1952-000 1→0 905-1
No Yes
New IMAGE PROCESSOR PCB FG6-1952-090 0→1
4 Old IMAGE PROCESSOR PCB FG6-1953-000 1→0 905-1
No Yes
New IMAGE PROCESSOR PCB FG6-1953-090 0→1
5 Old IMAGE PROCESSOR PCB FG6-5323-000 1→0 905-1
No Yes
New IMAGE PROCESSOR PCB FG6-5323-090 0→1
6 Old MFC PCB ASSEMBLY FG6-1916-000 1→0 905-1
No Yes
New MFC PCB ASSEMBLY FG6-1916-090 0→1
7 Old MFC PCB ASSEMBLY FG6-3565-000 1→0 905-1
No Yes
New MFC PCB ASSEMBLY FG6-3565-090 0→1
8 Old MFC PCB ASSEMBLY FG6-3566-000 1→0 905-1
No Yes
New MFC PCB ASSEMBLY FG6-3566-090 0→1
9 Old MFC PCB ASSEMBLY FG6-1917-000 1→0 905-1
No Yes
New MFC PCB ASSEMBLY FG6-1917-090 0→1
10 Old MFC PCB ASSEMBLY FG6-1918-000 1→0 905-1
No Yes
New MFC PCB ASSEMBLY FG6-1918-090 0→1

– 3 / 4 –

Страница 4

GP605-015

Inter- P.C.
No. Description Part number Q’ty change- — — — — — — — — —
ability
11 Old MFC PCB ASSEMBLY FG6-1919-000 1→0 905-1
No Yes
New MFC PCB ASSEMBLY FG6-1919-090 0→1
12 Old DIMM ASS’Y MBM29F080-90PFTN FG6-1955-000 1→0 905-1
No Yes
New DIMM ASS’Y MBM29F080-90PFTN FG6-1955-210 0→1
13 Old DIMM ASS’Y MBM29F080-90PFTN FG6-1956-000 1→0 905-1
No Yes
New DIMM ASS’Y MBM29F080-90PFTN FG6-1956-210 0→1
14 Old DIMM ASS’Y MBM29F080-90PFTN FG6-1957-000 1→0 905-1
No Yes
New DIMM ASS’Y MBM29F080-90PFTN FG6-1957-210 0→1
15 Old DIMM ASS’Y MBM29F080-90PFTN FG6-1958-000 1→0 905-1
No Yes
New DIMM ASS’Y MBM29F080-90PFTN FG6-1958-210 0→1
16 Old SYSTEM BOX ASSEMBLY FG6-1961-000 1→0 900-1
No Yes
New SYSTEM BOX ASSEMBLY FG6-1961-090 0→1
17 Old SYSTEM BOX ASSEMBLY FG6-1962-000 1→0 900-1
No Yes
New SYSTEM BOX ASSEMBLY FG6-1962-090 0→1
18 Old SYSTEM BOX ASSEMBLY FG6-1963-000 1→0 900-1
No Yes
New SYSTEM BOX ASSEMBLY FG6-1963-090 0→1
19 Old SYSTEM BOX ASSEMBLY FG6-1964-000 1→0 900-1
No Yes
New SYSTEM BOX ASSEMBLY FG6-1964-090 0→1
20 Old SYSTEM BOX ASSEMBLY FG6-3563-000 1→0 900-1
No Yes
New SYSTEM BOX ASSEMBLY FG6-3563-090 0→1
21 Old SYSTEM BOX ASSEMBLY FG6-3564-000 1→0 900-1
No Yes
New SYSTEM BOX ASSEMBLY FG6-3564-090 0→1

Affected machines:
[IP Ver. 20.11/MFC Ver. 20.05] [IP Ver. 21.01/MFC Ver. 21.02]
230V F13-5621 PLE00232 and later PLE00232 and later
F13-5641 PLP00224 and later PLP00254 and later
F13-5651 QLE00946 and later QLE00946 and later
F13-5661 RLE00137 and later RLE00175 and later
F13-5671 SLE00563 and later SLE00563 and later
F13-5681 TLE00318 and later TLE00318 and later
F13-5691 ULE01376 and later ULE01376 and later