Страница 1
1-1. Outline…………………………………………………………. 1-1
1-2. Guaranteed working conditions …………………….1-1
1-3. General specifications………………………………….. 1-2
1-4. Copy specifications ……………………………………… 1-2
1-5. Consumable parts specifications…………………..1-3
1-6. Option specifications ……………………………………1-3
1-7. Factory installed options specifications ……….. 1-3
Страница 2
1-1. Outline Developing unit and drum unit
This device is a compact desktop copier, which * When packed:
functions as an electrophotographic copy machine Store under conditions shown in the table below.
with the mirror zoom enlargement/reduction func- * When unpacked:
tion, document table fixed type optical section and Basically, the units should be installed in the
front loading paper feed method. main unit.
When storing as a single part after opening the
1-2. Guaranteed working conditions package, the normal temperature and humidity
conditions given below must be applied. Also, 1) Standard No. of printed copies per month :
note that it must be shielded from the light. 1,000 copies
2) Max. No. of printed copies per month :
5,000 copies
3) Machine service life: 150,000 copies Temperature:
or 5 years Normal (9/10 of total storage period)
4) Continuous copies : 1 ~ 99 copies 0~35oC
5) Machine operating environment Severe (1/10 of total storage period)
Temperature:10~30oC, Humidity: 30~80%RH High temperature : 35~40oC
* With no dew condensation. Low temperature : -10~0oC
6) Storage conditions (storage place)
When storing the packaged part for a long time, Tolerable temperature fluctuation (3 min. or
store the unit indoors. As a principle, maintain a more): 40oC→15oC
constant temperature and constant humidity, and -10oC→25oC
take special care to prevent water, dust and wind.
Avoid installing the unit in the places can be Humidity:
exposed to the direct rays or vigorous vibration. Normal (9/10 of total storage period)
(The storage conditions required in this item also 20~80%
apply to transportation.) Severe (1/10 of total storage period)
High humidity : 80~95%
Main unit storage conditions Low humidity : 5~20%
Atmospheric pressure: 613~1013hPa Temperature:
Normal (9/10 of total storage period)
Storage period: One year 0~35oC
Severe (1/10 of total storage period)
* Humidity: With no dew condensation High temperature : 35~45oC
Low temperature : -10~0oC
7) Working power supply
(Power supply range): 120V± 10% Tolerable temperature fluctuation (3 min. or
230V + 10.6% / -14% more): 45oC→15oC
-10oC→25oC (Voltage fluctuation range)
When the device is at the max. load, the voltage
drop must be within 3% in respect to the no-load Humidity:
state. Normal (9/10 of total storage period)
(Frequency range) 20~80%
Waveform: Sine wave, distortion Severe (1/10 of total storage period)
5% or less High humidity : 80~95%
Frequency: 60Hz±2Hz (USA) Low humidity : 5~20%
50/60Hz±2Hz (EU)
8) Installation conditions Atmospheric pressure: 613~1013hPa
1. Avoid high temperature/high humidity places, or
low temperature/low humidity places. Storage period: One year
2. Avoid installing the units in the place where they
can be exposed to the direct rays, or near heat * Excluding developing unit and drum unit
sources such as stoves or heaters. Humidity: With no dew condensation
3. Avoid installing the units in the places having
high dust levels.
4. Avoid installing the units in the places where the
temperature changes suddenly.
1-1
Страница 3
5. Do not install in the places where the unit can be 512) Cleaning system : Blade cleaning system
exposed to the direct blow-off from air-condition- 13) Platen : Stationary
ers, heating appliances or ventilation ports. 14) Copy document : Sheet, book (Max. B4/LG
6. Leave at least 20cm or more between the unit size)
and wall so that the intake to the unit and 15) Copy size : Max. A4/LG size
exhaust from the unit is not obstructed. 16) Paper feed :
7. Avoid installing the units in the places exposed (Paper feed system)
to vigorous vibration. 1-step cassette: Claw separation U-turn
8. Do not install on a place where the floor or paper feed system
foundation is unstable or not level. The inclina- Manual paper feed system:
tion angle must be within 1 degree, and the Slip roller feed system
flatness within 2mm. 1 (Copy paper size)
9) Designated consumable parts Always use the Cassette: LG, LT, A4, B5, A5
designated consumable parts. F:8 x13"(203 x 330mm)
10) Copy paper characteristics 8 1/2 x 13"(216x330mm)
Weight range: 60 ~ 80g/m2 8 1/4 x 13"(210x330mm)
Dimensional error: ±1mm (when using cassette) 206 x 337mm
±2mm (when using manual Manual feed: LG to A6
feed) (Min. paper passing
Angle: 90o±0.2o length: 140mm,
(Caution) The paper other than the standard Min.paper passing width:
designated one will not be subject to the reliabil- 95mm)
ity evaluation. (Copy paper capacity)
Standard: 250 sheets x 1 cassette
1 (Double-sided copying) + 1 manual feed sheet
* Use the manual feed tray. Option: 250 sheets x 1 cassette
* Use the standard designated paper. 1 (Copy paper weight)
* Make sure that the paper is not warped, torn, Cassette: 60 ~ 80g/m2
wrinkled or cut. Manual feed: 60 ~ 128g/m2,
* Paper that has been exposed to a highly humid 1 17) Paper exit tray
environment cannot be used. Paper exit capacity: 50 sheets(80g/m2)
Paper exit surface: Face up
18) Warm up time: Approx. 20 sec. (ambient
environment 23oC)
1-3. General specifications 19) Power consumption: Max. 1.3KW
1) Type : Desktop type, front 1 20) Outline dimensions
loading (Including manual feed guide):
2) Copying system : Indirect electrostatic 583(w) x 536(D) x 343(H)mm
method (Package dimensions): 768(w) x 694(D) x 480(H)mm
3) Photoconductor : Organic Photoconductor 1 21) Weight: Approx. 29.2Kg(Including
4) Charging system : DC negative corona toner, developer and drum)
with scorotron system Packed: Approx. 37.2Kg, excluding
5) Development system : Dry type two-element developer and toner)
magnetic brush
development method
6) Toner control system : Magnetic flux density 1-4. Copy specifications
detection system
1) Copy speed: LT/A4 12 sheets/min.
7) Toner collection system:
LG 10 sheets/min.
Recycle system
2) First copy time: A4/LT 7.9 sec.
8) Image traceability : Corresponding to 15%
3) Exposure system: Mirror scanning, slit exposure.
or less of document
4) Zoom:
B/W ratio
Fixed zoom: Enlargement
9) Transfer system : DC transfer roller system
129%(USA)
10) Paper sperating system :
141%(EU)
Curvature separation
Reduction
11) Fusing system : Heat roller fusing system
77%(USA)
82%,71%(EU)
Random zoom: 70% ~ 141%, 1 % increments
MODEL MANUAL REVISED EDITION DATA PAGE METHOD
1-2
1312 SERVICE HANDBOOK 1 May.1999 1-2 REPLACEMENT
Страница 4
5) Light source: Halogen lamp SDH(Single document handler)
6) Platen: Stationary This service handbook includes Konica 1312F
7) Document type: Sheet, book information that will be commercialized with SDH
8) Document weight: Max. 2Kg function.
9) Copy size: Max. A4/LG size
10) Density selection: Manual selection Note:These specifications are subject to change
11) Continuous copies: 1~ 99 copies without notice.
1-5. Consumable parts specifications
1) Toner cartridge
Life: 5,000 sheets(B/W 6%,
A4/LT size)
(Cautions for handling)
* Store in a cool, dark place with low humidity.
* Shake well before use.
* Always follow the instruction manual
2) Developing unit and drum unit
Life: 25,000 sheets
1-6. Option specifications
Cassette feeder (PF-105 / 105H)
1) Paper size: LG, LT, A4, B5, A5
F: 8 x13"(203 x 330mm)
8 1/2 x 13"(216x330mm)
8 1/4 x 13"(210x330mm)
206 x 337mm
2) Paper weight: 60 ~ 80g/m2
3) Cassette capacity: 250 sheets
4) Outline dimensions: 501(w) x 508(D) x 96(H)mm
* Excluding projections
5) Weight: 4.6Kg
* Excluding packing materials
6) Power supply: Supplied from main unit
24VDC 400mA(Max)
5VDC 100mA(Max)
1-7. Factory installed options specifications
Cassette heater
1) Heater type: PTC element (Posi-star
thermistor)
2) Power supply: 100 ~ 240VAC 50/60Hz
Max. 15W
3) Power ON method: Power ON constantly
including when main power
switch is OFF
1 4) Layout: Below main unit cassette
(Other than Europe,
America and Oceania
distination)
and cassette feeder.
(Only for PF-105H)
MODEL MANUAL REVISED EDITION DATA PAGE METHOD
1-3
1312 SERVICE HANDBOOK 1 May.1999 1-3 REPLACEMENT