Сервисный документ: Kyocera / Mita DC5090. Документ 34. Полный текст для поиска и оригинальный файл PDF для скачивания.
Kyocera / Mita · Сервисный документ · 4 стр. · PDF
Ниже приведён текст исходного документа. Схемы, иллюстрации и исходное расположение таблиц сохранены в файле для скачивания.
Текст документа
Страница 1
3-4-1 Replacing the main PCB
After replacing the main PCB, remove the backup PCB from the old main PCB and fit it
to the new main PCB. If the new backup PCB is used, perform the following steps.
<Procedure>
• Before removing the old backup PCB:
1. Record the user settings of the following items which must be reentered after
replacement.
• Program memory
• Initial mode selection
• Copy management setting
2. Enter simulation mode.
3. Run the following simulations and record the counts.
Sim. No. Contents
68 Developing drive time
72 Maintenance count
74 Jam counts
76 Service call counts
77 Copy counts by paper source
78 RDH and sorter counts
79 Setting the maintenance near indication
4. Exit simulation mode.
5. Turn the main switch off and unplug the power cord.
6. Replace the backup PCB with the new one.
3-4-1
Страница 2
• After installing the new backup PCB:
7. Insert the power plug and turn the main switch on.
8. Enter simulation mode.
9. Run simulation 70.
10. Run simulation 93 to select the destination.
Caution: Running simulation 93 changes the settings in simulations 79, 80, 84, 85, 92
and 94 (Setting the number of exposure steps) as follows.
93 Setting the 79 Setting the 80 Switching 84 Setting the auto
destination maintenance near between clear time
indication double/single
counts
Japan models 0 Single count 120 s
Inch models 0 Double count 90 s
Metric models 0 Double count 90 s
Asia pacific 0 Double count 90 s
93 Setting the 85 Setting the auto 85 Setting the 94 Setting the number
destination preheat/energy between auto of exposure steps
saver time start on/off
Japan models ON ON NORMAL MODE
Inch models ON ON SPECIAL MODE
Metric models ON ON SPECIAL MODE
Asia pacific ON ON SPECIAL MODE
11. Run the following simulation. Reenter the adjustment data recorded on the
simulation label and the contents in step 3.
Sim. No. Contents
09 Setting machine number
14 Setting folio size (metric models only)
15 Adjusting the slack amount before registration
18 Adjusting for duplex unit
24 Setting exposure amount (for equal magnification mode)
25 Adjusting lateral magnification
26 Adjusting longitudinal magnification
27 Adjusting appropriate exposure (Light potential)
28 Setting the lens unit rank
29 Adjusting the exposure amount for enlargement/reduction mode
31 Adjusting transfer timing
32 Adjusting the drum surface potential
52 Adjusting DF registration
54 Setting blank cut margins
56 Adjusting the leading edge registration
58 Selecting the key card/key counter
59 Setting punch hole modes
3-4-2
Страница 3
Sim. No. Contents
62 Settingthetonersensorcontrolreferencevoltage
64 Adjusting developing bias voltage
68 Checking/setting developing drive time
69 Setting/checking the developer maintenance count
71 Setting the maintenance counter preset value
72 Checking/clearing the maintenance count
74 Checking/clearing jam counts
75 Setting the service call phone No.
76 Changing/clearing service call counts
77 Changing/clearing copy counts by paper source
78 Changing/clearing counts by RDH or sorter
79 Setting the maintenance near indication
80 Switching between double/single count
81 Selecting newspaper original exposure mode
84 Setting the auto clear time
85 Setting the auto preheat/energy saver time
89 Selecting between paper feed/eject count
90 Ignoring the self-diagnostic function
91 Setting operation under the toner empty condition
92 Setting between auto start on/off
93 Setting the destination
94 Switching modes
12. Exit simulation mode.
13. Reenter the contents of the user settings recorded in step 1.
3-4-3
Страница 4
3-4-2 Adjustment-free variable resistors (VR)
The variable resistors listed below are set at the factory prior to shipping and cannot be
adjusted in the field.
• Composite PCB : VR1, VR501, VR502, VR503
• High-voltage transformer PCB: VR101, VR102, VR201, VR202, VR301, VR401
• Transfer charger belt bias PCB: VR1, VR501
3-4-4