Страница 1

2BT
1-5-2 Self-diagnosis

(1) Self-diagnostic function
This unit is equipped with a self-diagnostic function. When a problem is detected, copying is disabled. "C" and a number
between 011 and 731 altenates, indicating the nature of the problem.
After removing the problem, the self-diagnostic function can be reset by turning safety switch off and back on.

(2) Self diagnostic codes
Remarks
Code Contents
Causes Check procedures/corrective measures
A011 Backup memory data problem Problem with the Turn safety switch off and back on and run
(C011) • Data in the specified area of the backup memory maintenance item U020 to set the contents
backup memory does not match the data. of the backup memory data again.
specified values. Defective backup If the C011 is displayed after re-setting the
RAM. backup memory contents, replace the
backup RAM.
A100 Exposure lamp problem Poor contact of Check the connection of connector CN12
(C100) • Check the CCD input value for the the connector on the main PCB, and the continuity across
lighting status of the exposure lamp terminals. the connector terminals. Repair or replace
100 ms after the exposure lamp is lit if necessary.
and the carriage is moved to the Defective Replace the exposure lamp. shading position. If the exposure lamp exposure lamp. does not light, turn off the lamp. After
500 ms, light the lamp again and, a Defective main Replace the main PCB or inverter PCB and
further 500 ms later, check the CCD PCB or inverter check for correct operation.
input. PCB.
The exposure lamp does not light Incorrect shading Adjust the position of the contact glass after 5 retries. position. (shading plate). If the problem still occurs,
replace the scanner home position switch.
CCD PCB output Replace the ISU.
problem.
A104 Optical system problem Poor contact of Check the connection of connector CN12
(C104) • After AGC, correct input is not the connector on the main PCB, and the continuity across
obtained at CCD. terminals. the connector terminals. Repair or replace
if necessary.
Defective Replace the exposure lamp.
exposure lamp.
Defective main Replace the main PCB or inverter PCB and
PCB or inverter check for correct operation.
PCB.
Incorrect shading Adjust the position of the contact glass
position. (shading plate). If the problem still occurs,
replace the scanner home position switch.
CCD PCB output Replace the ISU.
problem.

1-5-7

Страница 2

2BT

Remarks
Code Contents
Causes Check procedures/corrective measures
A310 Scanner carriage problem Poor contact of Check the connection of connector CN15
(C310) • The home position is not correct the connector on the main PCB and the continuity across
when the power is turned on or at the terminals. the connector terminals. Remedy or
start of copying using the contact replace if necessary.
glass. Defective scanner Replace the scanner home position switch.
home position
switch.
Defective main Replace the main PCB and check for
PCB. correct operation.
Defective scanner Replace the scanner motor.
motor.
A400 Polygon motor synchronization Poor contact of Check the connection of connector CN3 on
(C400) problem the connector the main PCB and the continuity across the
• The polygon motor does not reach a terminals. connector terminals. Remedy or replace if
stable speed within 19 s of the polygon necessary.
motor remote signal turning on. Defective polygon Replace the LSU.
motor.
Defective power Check if 24 V DC is present at CN1-2 on
source PCB. the power source PCB. If not, replace the
power source PCB.
A401 Polygon motor steady-state problem Poor contact of Check the connection of connector CN3 on
(C401) • The polygon motor rotation is not the connector the main PCB and the continuity across the
stable for 400 ms after the polygon terminals. connector terminals. Remedy or replace if
motor rotation has been stabilized. necessary.
Defective polygon Replace the LSU.
motor.
Defective power Check if 24 V DC is present at CN1-2 on
source PCB. the power source PCB. If not, replace the
power source PCB.
A420 BD steady-state problem Poor contact of Check the connection of connector CN18
(C420) • The VTC detects a BD error for 800 the connector on the main PCB and the continuity across
ms after the polygon motor rotation terminals. the connector terminals. Remedy or
has been stabilizad. replace if necessary.
Defective LSU. Replace the LSU.
Defective main Replace the main PCB and check for
PCB. correct operation.
A510 Main charger problem Poor contact of Reinsert the connector. Also check for
(C510) • MC ALM signal is detected the high-voltage continuity within the connector cable. If
continuously for 800 ms when MC transformer PCB none, repair or replace the cable.
REM signal is turned on. connector
terminals.
Defective high- Replace the high-voltage transformer
voltage PCB.
transformer PCB.
Leakage during Check and clean the main charger unit.
main charging.

1-5-8

Страница 3

2BT

Remarks
Code Contents
Causes Check procedures/corrective measures
A510 Main charger problem Deformed high- Replace the spring.
(C510) • MC ALM signal is detected voltage
continuously for 800 ms when MC transformer PCB
REM signal is turned on. terminal spring.
C610 Broken fixing heater wire Fixing heater Check and reinstall if necessary.
• It takes 15 s or more for the fixing installed
temperature to reach 50°C/122°F incorrectly.
after the power is turned on or the Broken fixing Check for continuity. If none, replace fixing safety switch is turned off and on. heater wire. heater. • It takes 10 s or more for the fixing
temperature to reach 100°C/212°F Poor contact in Check the connection of connector CN11
from 50°C/122°F. the fixing unit on the main PCB and the continuity across
• It takes 24 s or more for the fixing thermistor the connector terminals. Remedy or
temperature to reach the secondary connector replace if necessary.
stabilization fixing temperature from terminals.
the primary stabilization fixing Broken fixing unit Measure the resistance. If it is ∞ Ω, replace temperature. thermistor wire. the fixing unit thermistor.
Fixing unit Check and reinstall if necessary.
thermistor
installed
incorrectly.
Fixing unit Check for continuity. If none, replace the
thermostat fixing unit thermostat.
triggered.
C620 Abnormally low fixing unit Fixing heater Check and reinstall if necessary.
thermistor temperature installed
• The fixing temperature remains below incorrectly.
90°C/194°F for 10 s during copying. Broken fixing Check for continuity. If none, replace fixing
heater wire. heater.
Poor contact in Check the connection of connector CN11
the fixing unit on the main PCB and the continuity across
thermistor the connector terminals. Remedy or
connector replace if necessary.
terminals.
Broken fixing unit Measure the resistance. If it is ∞Ω, replace
thermistor wire. the fixing unit thermistor.
Fixing unit Check and reinstall if necessary.
thermistor
installed
incorrectly.
Fixing unit Check for continuity. If none, replace the
thermostat fixing unit thermostat.
triggered.
C630 Abnormally high fixing unit Shorted fixing unit Measure the resistance. If it is 0 Ω, replace
thermistor temperature thermistor. the fixing unit thermistor.
• The fixing temperature exceeds Broken fixing Replace the power source PCB. 230°C/446°F for 10 s. heater control
circuit on the
power source
PCB.

1-5-9

Страница 4

2BT

Remarks
Code Contents
Causes Check procedures/corrective measures
C710 Toner sensor problem Defective toner Replace the toner sensor.
• The sensor output voltage is outside sensor.
the range of 0.5 to 4.5 V during toner Poor contact of Reinsert the connector. Also check for control. the toner sensor continuity within the connector cable. If • The toner sensor control voltage connector none, repair or replace the cable. cannot be set within the setting range terminals. when maintenance item U130 is run.
Developer Replace the developer.
problem.
A730 Broken external temperature Poor contact of Reinsert the connector. Also check for
(C730) thermistor wire the humidity continuity within the connector cable. If
• The input voltage is above 4.5 V. sensor PCB none, repair or replace the cable.
connector
terminals.
Defective external Replace the humidity sensor PCB.
temperature
thermistor.
A731 Short-circuited external temperature Poor contact of Reinsert the connector. Also check for
(C731) thermistor the humidity continuity within the connector cable. If
• The input voltage is below 0.5 V. sensor PCB none, repair or replace the cable.
connector
terminals.
Defective external Replace the humidity sensor PCB.
temperature
thermistor.

1-5-10