Патрон-сервис. Техника и электроникаСервисный центр · Луганск
Наш телефон+7 959 128-10-50
Рабочее времяПн–пт 9:00–17:00
Сб 10:00–14:00
Патрон-сервис · Луганск

Kyocera / Mita KM1530 / 2030 — сервисный документ Fax B – KM2030 – C Errors

Kyocera / MitaСервисный документ2 стр.

Сервисный документ: Kyocera / Mita KM1530 / 2030. Документ Fax B – KM2030 – C Errors. Полный текст для поиска и оригинальный файл PDF для скачивания.

Kyocera / Mita · Сервисный документ · 2 стр. · PDF

Скачать PDF (0.0 МБ)

Ниже приведён текст исходного документа. Схемы, иллюстрации и исходное расположение таблиц сохранены в файле для скачивания.

Текст документа

Страница 1

3B1

Remarks
Code Contents
Causes Check procedures/corrective measures
C083 Flash ROM program area checksum Defective SRAM Replace the fax control PCB and check for
error on the fax control correct operation.
• A checksum error occurred with the PCB.
program in the flash ROM on the fax
control PCB.

1-5

1-5-2

Страница 2

3B1
1-5-1 Self-diagnosis

(1) Self diagnostic codes
Remarks
Code Contents
Causes Check procedures/corrective measures
C003 Fax control PCB system problem Defective fax con- Replace the fax control PCB and check for
• Processing with the fax software was trol PCB. correct operation.
disabled due to a hardware or soft-
ware problem.
C005 Communication problem between Defective fax con- Replace the fax control PCB and check for
the operation unit PCB and fax con- trol PCB. correct operation.
trol PCB
• The operation unit PCB did not re-
ceive any key request command from
the fax control PCB within 1 minute of
the status change signal turning on.
Then, after resetting the fax machine,
the operation unit PCB again did not
receive any key request command
from the fax control PCB while the
status change signal was held on for
1 minute.
• Abnormal data was received 5 times
in succession in response to the com-
mand from the fax control PCB.
• An erroneous FAX READY signal
continued for 3 seconds and, after
resetting the fax machine, an errone-
ous FAX READY signal continued for
3 seconds again.
C006 Communication problem between Defective fax con- Replace the fax control PCB and check for 1-5
the main PCB and fax control PCB trol PCB. correct operation.
When the facsimile is in the condition
given below, the correct status was not
received after 5 transmission retries.
• When a communication error, such as
a parity error, occurs while receiving
status.
• When no status is sent back within
100 ms of sending a command.
• When the interval of status reception
data exceeds 30 ms.
C013 Fax control PCB software switch Defective SRAM Replace the fax control PCB and check for
checksum error on the fax control correct operation.
• A checksum error occurred with the PCB.
software switch value stored in the
flash ROM on the fax control PCB.
C082 Fax control PCB CG ROM checksum Defective fax con- Replace the fax control PCB and check for
error trol PCB. correct operation.
• A checksum error occurred with the
CG ROM data in the flash ROM on
the fax control PCB.

1-5-1

График работыПн–пт 9:00–17:00
Сб 10:00–14:00
Напишите на почтуmail@patronlg.ru
Ждём вас в мастерскойЛуганск, ул. Газеты
Луганская Правда, 153В
Позвонить в Патрон-сервис
Заказать звонок
+