Сервисный документ: Riso RN. Документ 10. Полный текст для поиска и оригинальный файл PDF для скачивания.
Riso · Сервисный документ · 16 стр. · PDF
Ниже приведён текст исходного документа. Схемы, иллюстрации и исходное расположение таблиц сохранены в файле для скачивания.
Переход к странице документа
Текст документа
Страница 1
Contents
Mechanism …………………………………………………………………………………………………………. 10-2
1. Master Removal Mechanism ……………………………………………………………………… 10-2
2. Master on the Drum (before Master Removal) Check Mechanism …………………. 10-3
3. Removed Master Vertical Transport Mechanism ………………………………………….. 10-4
4. Disposed Master Compression Mechanism ………………………………………………. 10-5
5. Disposal Box Safety Switch ……………………………………………………………………….. 10-8
Removal and Assembly ……………………………………………………………………………………….. 10-9
1. Removing the Master Removal Hook …………………………………………………………. 10-9
2. Removing the Master Removal Unit………………………………………………………….. 10-10
3. Removing the Master Disposal Gate Housing …………………………………………… 10-12
4. Removing the Master Removal Roller (Bottom) …………………………………………. 10-13
5. Removing the Master Compression Plate …………………………………………………. 10-14
6. Removing the Motors ………………………………………………………………………………. 10-16
10 – 1
RN (Version 1.0)
Страница 2
MASTER REMOVAL MECHANISM
Mechanism
1. Master Removal Mechanism
Masters on the print drum are removed as follows.
(1) At the start of master removal, the Master sensor [A] checks whether the master to be removed on the
print drum actually exists.
(2) The clamp plate master removal operation is performed with the print drum at position A to release
the leading edge of the master from the clamp plate.
(3) The Master removal hook [B] then detaches the master from the print drum as the drum is rotated.
(4) The removed master is fed into the Master compression plate [C].
(5) The removed master is then compressed, and disposed of in the Master disposal box [D].
B
A
C
D
A: Master sensor
B: Master removal hook
C: Master compression plate
D: Master disposal box
–10 – 2
RN (Version 1.0)
Страница 3
MASTER ON THE DRUM (BEFORE MASTER REMOVAL) CHECK MECHANISM
2. Master on the Drum (before Master Removal) Check Mecha-
nism
When creating confidential or normal masters, the print drum moves to position A, and with the print drum
at the 75° position, the Master sensor [A] checks whether or not there is a master [B] on the drum. (The
check operation is not performed if information that a master is present has already been stored in the
machine’s memory.) The drum rotation angle for the check can be adjusted using test mode No. 580.
If the light from the Master sensor [B] is reflected back, (master present), the master removal sensor
checks whether the master is sent to the master disposal box or not during the master removal.
A
B
Print drum
75° position
C
A: Master sensor
B: Master
C: Light absorber strip
10 – 3
RN (Version 1.0)
Страница 4
REMOVED MASTER VERTICAL TRANSPORT MECHANISM
3. Removed Master Vertical Transport Mechanism
When the clamp unit is operated to release the leading edge of the master from the clamp plate, the
Master removal motor [A] activates, rotating the Vertical transport rollers [B, C, D, E, F]. The main motor
also rotates the print drum at the same time.
The master is fed between the rollers and pushed into the Master compression plate [H].
The master is guided here by the Master removal hook [G] and G belt [J].
The main motor and Master removal motor [A] stop once the print drum has rotated to position-A. (The
time at which the master removal motor stops can be adjusted using test mode No. 382.)
When the print drum reaches the 70° and 90° positions, the Master removal sensor [I] checks whether the
master is being fed correctly to the master disposal box. (These drum angles can be adjusted using test
modes No. 380 and 381.)
The master removal hook is normally located at a fixed position close to the print drum, but shifts away
from the drum when the drum is pulled out.
The print drum rotation speed during master removal can be adjusted using test mode No. 387.
D I C J B
H
G E F
A: Master removal motor
B: Pulley shaft
C: Master removal roller (top)
D: Master removal pulley (top) A
E: Master removal pulley (bottom)
F: Master removal roller (bottom)
G: Master removal hook
H: Master compression plate
I: Master removal sensor
J: G belt
10 – 4
RN (Version 1.0)
Страница 5
DISPOSED MASTER COMPRESSION MECHANISM
4. Disposed Master Compression Mechanism
1) Initializing
• If the light path on the Master compression sensor [B] is open when the power is switched ON or
when everything is reset, the master compression motor operates in the compression direction,
and when the light path to the master compression sensor is blocked, it operates in reverse until
the light path is open again.
• If the light path to the Master compression sensor [B] is blocked when the power is switched ON or
when everything is reset, the master compression motor operates in the return direction until the
light path is open again.
• If the light path to the Master compression sensor [B] is blocked when starting master removal, the
master compression motor operates in the return direction until the light path is open. (The initializ-
ing operation is not performed if the light path to the master compression sensor is open when
starting master removal.)
2) Master compression
Once the removed master vertical transport operation is complete, the master compression motor
operates in the compression direction to lower the Master compression plate [A]. The light path to
the master compression sensor is briefly blocked by the Master compression sensor plate [C].
When the light path to the master compression sensor is subsequently opened again, the master
compression motor stops (the stop time can be adjusted using test mode No. 384), and then
operates in the return direction to return the master compression plate to its home position.
3) Ejection of removed master
The master removed by the vertical transport operation is pushed inside the Master compression
plate [A]. Compression is performed by the master removal motor rotating the Master compression
plate [A] on the Pivot shaft [D]. The Piston shaft link [E] also rotates, but it rotates on the Piston shaft
[F] rather than on the Pivot shaft [D]. This causes the Piston block [G] to move in the direction in
which the master ejects out.
C B A
D
A: Master compression plate
B: Master compression sensor
F
C: Master compression sensor plate
D: Pivot shaft
E: Piston shaft link E
F: Piston shaft
G: Piston block
G
10 – 5
RN (Version 1.0)
Страница 6
DISPOSED MASTER COMPRESSION MECHANISM
4) Disposed-master-full detection
The removed-master-full detection is performed using the following two mechanisms, and a master-
full indication is displayed by either.
(1) The number of masters removed after resetting following the previous master-full indication is
counted, and the master disposal box is determined as full when the count reaches the preset
value.
* The preset master-full count can be set using test mode No. 386.
The master count is not incremented if a master removal error occurs or if the master to be
removed is not detected on the print drum.
(2) Mechanism for mechanically determining that the master disposal box is full (see below.)
Master compression sensor
Disposal box full Master compression sensor plate
sensor
At the start of compression, the light paths to the
master compression sensor and disposal box full
sensors are open.
Master compression plate
Pivot shaft
When the master compression motor operates to start
master compression, the master compression
sensor is immediately blocked by the master
compression sensor plate. As the operation
continues, the disposal box full sensor is briefly
blocked by the master compression plate, but is then
opened.
Once the master inside the master disposal box has
been sufficiently compressed, the master
compression plate stops rotating, but the master
compression sensor plate continues to rotate.
(The master compression plate is mounted to the
pivot shaft via a spring, whereas the master
compression sensor plate is mounted directly to the
pivot shaft.)
Once the light beam of the master compression
sensor is blocked by the master compression sensor
plate, the compression operation stops, and the
master compression plate returns to the home
position.
10 – 6
RN (Version 1.0)
Страница 7
DISPOSED MASTER COMPRESSION MECHANISM
When the master disposal box becomes full, the
master compression plate stops rotating before the
removed-master-full sensor is blocked.
When the light path to the master compression
sensor is open and the removed-master-full sensor is
not blocked, the master-disposal-box-full indication is
displayed.
10 – 7
RN (Version 1.0)
Страница 8
DISPOSAL BOX SAFETY SWITCH
5. Disposal Box Safety Switch
The master disposal box safety switch checks whether the master disposal box and master disposal
gate housing are properly positioned.
If the master disposal gate housing is locked and correctly set, the bracket on the master disposal gate
housing is positioned close to the safety switch.
When the master disposal box is mounted, the safety switch unit moves back, and the safety switch is
pushed against the master disposal gate housing.
The master disposal box full indication is reset if the master disposal box safety switch is released (the
master disposal box removed) for more than 5 seconds. The master disposal box count memory is also
reset to zero.
Master disposal gate housing
Safety switch
Master disposal box
10 – 8
RN (Version 1.0)
Страница 9
REMOVING THE MASTER REMOVAL HOOK
Removal and Assembly
1. Removing the Master Removal Hook
(1) Pull out the print drum, switch off the power, and remove the front cover.
(2) Remove the spring [A] from the master removal hook bracket.
(3) Remove the bearing fixing plate [B]. (M4 x 8: 1 pc)
(4) Remove the Master removal hook [C] together with the master removal hook bracket. (If it cannot be
removed, it is caught on the front screw of the master removal unit mounting screws. Remove this
screw.)
[Precautions on Reassembly]
• Do not drop the inside bearing when mounting the master removal hook bracket.
A
B
C
A: Spring of the master removal hook bracket
B: Bearing fixing plate
C: Master removal hook bracket and master removal hook
10 – 9
RN (Version 1.0)
Страница 10
REMOVING THE MASTER REMOVAL UNIT
2. Removing the Master Removal Unit
(1) Move the scanner table to the servicing position [A].
(2) Remove the front and rear covers.
(3) Remove the upper housing cover (master removal unit cover). (M3 x 6: 2 pcs)
(4) Unlock the Release lever [B], fully open the Master disposal gate housing [C], and pull out the master
disposal gate housing horizontally in the direction of paper ejection. The master disposal gate
housing is slotted into the Pivot shafts [D] on both sides. The shafts are cut as shown in the diagram
below, and so the master disposal gate housing can be pulled out provided it is opened sufficiently.
A
B
C
D
A: Servicing position
B: Release lever
C: Master disposal gate housing
D: Pivot shaft
10 – 10
RN (Version 1.0)
Страница 11
REMOVING THE MASTER REMOVAL UNIT
(5) Remove the master removal unit mounting screws (M4 x 8: 4 pcs).
(6) Detach the connectors on both sides, and remove the master removal unit.
10 – 11
RN (Version 1.0)
Страница 12
REMOVING THE MASTER DISPOSAL GATE HOUSING
3. Removing the Master Disposal Gate Housing
(1) Remove the E-rings and bearings on both sides of the Pulley shaft [B], and remove the Pulley shaft.
(2) Remove the E-rings, bearings, and gears on both sides of the Master removal roller (top) [A], and
remove the roller.
(3) Remove the G belts [D] from the Master removal pulleys (top) [C].
C
A D B E
A: Master removal roller (top)
B: Pulley shaft
C: Master removal pulleys (top)
D: G belts
E: Master disposal gate housing
10 – 12
RN (Version 1.0)
Страница 13
REMOVING THE MASTER REMOVAL ROLLER (BOTTOM)
4. Removing the Master Removal Roller (Bottom)
(1) Loosen the screws on the Tension roller [A], and remove the belt [B]. (M3 x 6: 2 pcs)
(2) Remove the E-rings, bearings, gears, and pulleys on both sides of the Master removal roller (bottom)
[C], and remove the roller.
(3) Remove the G belts [D].
B
A
D
C
A: Tension roller
B: Belt
C: Master removal roller (bottom)
D: G belt
10 – 13
RN (Version 1.0)
Страница 14
REMOVING THE MASTER COMPRESSION PLATE
5. Removing the Master Compression Plate
(1) Remove the E-rings and bearings from both sides of the compression shaft [A].
(2) Rotate the compression shaft to move the master Compression plate [C] to the master compressing
position.
Lifting up the compression gear [B] together with the shaft, to disengage the gear, allowing the shaft
to be rotated.
(3) Remove the E-rings on both sides of the Piston shaft [D], and remove the shaft.
(4) Remove the Piston shaft links [E] on both sides.
J A
C
B
D
E
10 – 14
RN (Version 1.0)
Страница 15
REMOVING THE MASTER COMPRESSION PLATE
(5) Remove the shaft from the unit, with the master compression plate attached.
C
(6) Remove the Piston blocks [F].
(7) Unhook the Compression spring [H] from the Compression plate holder [G], and then remove the
compression plate holder from the Compression shaft [A].
(8) Remove the Master compression sensor plate [I] and then separate the Master compression plate
from the compression shaft.
F
C
I
G H
A: Compression shaft
B: Compression gear
C: Master compression plate
D: Piston shaft
E: Piston shaft link
F: Piston block
G: Compression plate holder
H: Compression spring
I: Master compression sensor plate
J: Compression plate guard cover (* master anti-clamping component)
10 – 15
RN (Version 1.0)
Страница 16
REMOVING THE MOTORS
6. Removing the Motors
(1) Remove the Master removal motor [A]. (Mounting screws M4 x 6: 2 pcs)
(2) Remove the Compression motor [B]. (Mounting screws M4 x 6: 2 pcs)
(3) Remove the E-rings, and then remove the Safety switch unit [C].
C B A
A: Master removal motor
B: Compression motor
C: Safety switch unit
10 – 16