Технический бюллетень. Minolta Di620. Документ 1155038. Тема: C0110 DISPLAY.
Minolta · Технический бюллетень · 1 стр. · PDF
Ниже приведён текст исходного документа. Схемы, иллюстрации и исходное расположение таблиц сохранены в файле для скачивания.
Текст документа
Страница 1
PAGE NO. : 1/1
SERVICE BULLETIN
PROBLEM FUNCTION SAFETY
SERVICEABILITY OTHERS
MODEL NAME : Di620 OTHERS PERFORMANCE CORRECTION
MODEL CODE : 1155 SAFETY REGULATION OTHERS
NO. : 038
DATE : 990714
SUBJECT : C0110 DISPLAY
PROBLEM: There is a possibility that malfunction “C0110” may at times occur due to the malfunctioning corona wire
cleaning mechanism of the image transfer/paper separator coronas unit (01).
CAUSE: The corona wire cleaner moves back and forth on the corona wire, controlled as detailed below. If,
however, there are variations in the accuracy of parts of the image transfer/paper separator coronas unit
(01), the cleaner reaches the very end of the screw of the transport shaft (02) and goes beyond the screw
part before 11.6 sec. elapse after the cleaning motor (M8) has started turning forward.
SOLUTION: The screw part of the transport shaft (02) has been made longer to give allowance for the cleaner
motion.
01
Paper separator wire
Image transfer
corona wire 02
Screw part
Cleaner
02 355.2mm→360.1mm 16.9mm→12mm
Cleaning motor (M8)
BEFORE MODI. AFTER MODI. QTY
NO. F-IND PART NO. PART NO. F-IND PART NAME → I SE/NO. AREA
01 24-35AA 1155-0357-01 1155-0357-03 24-35AB TRANS/SEP CORONA 1 1 Y 255736 0000
02 24-26AA 1075-4161-02 1075-4161-03 24-26AB CONVEYOR SHAFT 1 1 Y 255736 0000
PCJ-242iA PRINTED IN JAPAN