Страница 1
4-1. Toner density…………………………………………………4-1
4-2. Fusing temperature ……………………………………….4-1
4-3. Exposure voltage …………………………………………..4-2
4-4. Image position……………………………………………….4-2
4-4-1. Center position …………………………………………..4-2
4-4-2. Leading edge position…………………………………4-3
4-4-3. Image skew…………………………………………………4-3
4-5. Magnification adjustment……………………………….4-3
4-5-1. Feeding direction (Vertical magnification) ……4-3
4-5-2. Crosswise direction
(Horizontal magnification) ……………………………4-4
4-6. Optical section adjustment …………………………….4-4
4-6-1. Light distribution ………………………………………..4-4
4-6-2. Scanner reference position …………………………4-5
4-6-3. Lens reference position ………………………………4-5
4-6-4. Diagonal distortion ……………………………………..4-5
4-6-5. Image distortion ………………………………………….4-5
4-6-6. Focus …………………………………………………………4-5
4-6-7. Image center position………………………………….4-6
4-6-8. Focus (Horizontal blurring)………………………….4-6
4-6-9. Horizontal magnification ……………………………..4-6
4-7. Leading and trailing edges erase width…………..4-6
Страница 2
4-1. Toner density 4-2. Fusing temperature
The toner density adjustment procedure is used to The fusing temperature adjustment is carried out to
adjust the black matte section density or the toner improve the fusing performance when copying onto
consumption amount, etc. thick paper, and to uncurl thin paper, etc.
1) Procedure 1) Procedure
1. Call out the service mode. 1. Call out the service mode.
(Press the Enlarge key and Reduce key for 5 sec. (Press the Enlarge key and Reduce key for 5 sec.
in the Scale 1: 1 mode, and press the 0 key within in the Scale 1: 1 mode, and press the 0 key within
2 sec. after the local destination displayed) 2 sec. after the local destination displayed)
Japan US Europe Japan US Europe
2. Select 25 mode. 2. Select 25 mode.
(Input 25 with the numeric keypad, and then press (Input 25 with the numeric keypad, and then press
the Start Print key.) the Start Print key.)
3. Select address 84 (toner density control setting). 1 3. Select address 80 (Fusing temperature control
(Input 84 with the numeric keypad, and then press setting).
the Start Print key.) (Input 80 with the numeric keypad, and then press
the Start Print key.)
4. Change the setting data to the required data (1 to 5).
(Input the data with the numeric keypad, and then 4. Change the setting data to the required data (1 to 5).
press the Start Print key.) (Input the data with the numeric keypad, and then
Data Toner density Data Fusing temperature Remarks
1 Lighter 1 182oC Lower
2 ↑ 2 185oC ↑
3 Default value 3 188oC Default value
4 ↓ 4 190oC ↓
5 Darker 5 193oC Higher
5. Press the Clear/Stop key until the normal mode press the Start Print key.)
appears (3 presses). 5. Press the Clear/Stop key until the normal mode
(When the Clear key is pressed once, the state appears (3 presses).
will return to the previous state.) (When the Clear key is pressed once, the state will
Note: After changing this setting, the changed return to the previous state.)
toner density will not be achieved immedi-
ately.
MODEL MANUAL REVISED EDITION DATA PAGE METHOD
4-1
1312 SERVICE HANDBOOK 1 May.1999 4-1 REPLACEMENT
Страница 3
4-3. Exposure voltage 4. Change the setting data to the required data (01 to
The exposure lamp voltage adjustment is carried out 64).
to change the adjustment width of the density control (Input the data with the numeric keypad, and then
knob on the operation panel. press the Start Print key.)
1) Procedure
1. Call out the service mode.
(Press the Enlarge key and Reduce key for 5
sec. in the Scale 1: 1 mode, and press the 0 key
Changed data Changed data is within 2 sec. after the local destination displayed)
(example: 42) blinks set
5. When the Start Print key is pressed again, a test
copy of the settings after the changes can be
Japan US Europe made.
6. After copying, the status will return to step 4. Thus,
2. Select 36 mode. if the density is not as required, repeat the proce-
(Input 36 with the numeric keypad, and then dure from step 4.
press the Start Print key.) 7. When completed with the adjustment, press the
Clear/Stop key until the normal mode appears (3
presses).
(When the Clear key is pressed once, the state
will return to the previous state.)
3. Select the code to be changed (86 to 90: AVR
4-4. Image position adjustment 1 to 5).
4-4-1. Center position (Example: Input 88 with the numeric keypad, and
then press the Start Print key.) If the position of the copy is mis-centered, adjust the
fixing position (four screws) of the document scale or
the cassette fixing position (two screws).
Adjustment data
(example: 32) blinks
1 Code Adjustment details Adjustment range Document Copy Copy
86 Center density in
enlargement.
(Adjustment range:
Approx. 43V to 67V)
87 Center density in
reduction.
(Adjustment range:
Approx. 43V to 67V)
88 Max. density in 01 to 64
life size.
(Adjustment range:
Approx. 55V to 80V)
89 Center density in
life size.
(Adjustment range:
Approx. 43V to 67V)
90 Min. density in Note: When adjusting the center position of a manual
life size. feed copy, since the manual feed guide is fixed,
(Adjustment range:
Approx. 30V to 55V) align the document scale to the manual feed
side first, and then align the cassette’s fixing
position.
MODEL MANUAL REVISED EDITION DATA PAGE METHOD
4-2
1312 SERVICE HANDBOOK 1 May.1999 4-2 REPLACEMENT
Страница 4
4-4-2. Leading edge position 7. When completed with the adjustment, press the
If the leading edge position of the copy is mis- Clear/Stop key until the normal mode appears (3
centered, change the edge adjustment data. pushes).
(When the Clear key is pressed once, the state will
return to the previous state.)
8. To adjust the leading edge for an enlarged or re-
duced copy, press the Scale key and Arrow key
o r
before step 4, and select the fixed scale enlarge-
ment or reduction.
Note: Enlargement or reduction can be carried out in
the zoom mode. However, as the scale 114% to Document Copy Copy
83% is a full size adjustment scale, set a scale
1) Procedure that exceeds this range.
1. Call out the service mode.
(Press the Enlarge key and Reduce key for 5 sec. 4-4-3. Image skew
in the Scale 1: 1 mode, and press the 0 key within The image skew caused by the document inclination
2 sec. after the local destination displayed) when it is placed on the platen is adjusted by chang-
ing the position of the document scale’s fixed posi-
tion (four screws).
Japan US Europe
o r
2. Select 36 mode.
(Input 36 with the numeric keypad, and then press
the Start Print key.)
Document Copy Copy
3. Select address 91 (leading edge position setting).
(Example: Input 91 with the numeric keypad, and then
press the Start Print key.)
4-5. Magnification adjustment
If the length of the copy is deviated from that of the
original in the feeding direction or the crosswise
direction, perform the magnification adjustment.
Adjustment data
(example: 32) blinks
4-5-1. Feeding direction (Vertical
magnification)
4. Change the setting data to the required data (01 to
64:adjustment width 5mm).
(Input the data with the numeric keypad, and then
press the Start Print key.)
Document Copy Copy
1) Procedure
Changed data Changed data is
1. Call out the service mode.
(example: 42) blinks set
(Press the Enlarge key and Reduce key for 5 sec.
5. When the Start Print key is pressed again, a test in the Scale 1: 1 mode, and press the 0 key within
copy of the settings after the changes can be 2 sec. after the local destination displayed)
made.
6. After copying, the status will return to step 4. Thus,
if the density is not as required, repeat the proce-
dure from step 4. Japan US Europe
4-3
Страница 5
2. Select 36 mode. 3. Select address 95 (lens home position adjustment).
(Input 36 with the numeric keypad, and then press (Example: Input 95 with the numeric keypad, and
the Start Print key.) then press the Start Print key.)
Adjustment data
3. Select address 93 (Scanner speed adjustment). (example: 32) blinks
(Example: Input 93 with the numeric keypad, and
then press the Start Print key.) 4. Change the setting data to the required data (01 to
64:adjustment width 5mm).
(Input the data with the numeric keypad, and then
press the Start Print key.)
Adjustment data
(example: 32) blinks
4. Change the setting data to the required data (01 to Changed data Changed data is
64:adjustment width 5mm). (example: 42) blinks set
(Input the data with the numeric keypad, and then
press the Start Print key.) 5. When the Start Print key is pressed again, a test
copy of the settings after the changes can be
made.
6. When the copy is done, the status will return to
step 4. Thus, if the density is not as required,
Changed data Changed data is repeat the procedure from step 4.
(example: 42) blinks set 7. When completed with the adjustment, press the
Clear/Stop key until the normal mode appears (3
5. When the Start Print key is pressed again, a test presses).
copy of the settings after the changes can be (When the Clear key is pressed once, the state will
made. return to the previous state.)
6. When the copy is done, the status will return to
step 4. Thus, if the density is not as required,
repeat the procedure from step 4. 4-6. Optical section adjustment
7. When completed with the adjustment, press the Note 1: As advanced adjustment skills are required
Clear/Stop key until the normal mode appears (3 for adjusting the optical section, avoid
presses). adjusting this section unless absolutely
(When the Clear key is pressed once, the state necessary.
will return to the previous state.) Note 2: Each of the adjustment places in the optical
section are marked with lock paint on screws,
so dissolve the lock paint using alcohol, etc.,
4-5-2. Crosswise direction (Horizontal before starting the adjustment. (Some
magnification) screws are resin.) Always apply screw lock
1) Procedure after the adjustments.
1. Call out the service mode.
(Press the Enlarge key and Reduce key for 5 sec. 4-6-1. Light distribution
in the Scale 1: 1 mode, and press the 0 key within If the light distribution of the exposure lamp is unbal-
2 sec. after the local destination displayed) anced, adjust the aperture plate, and even out the
half tone density.
Japan US Europe
2. Select 36 mode.
(Input 36 with the numeric keypad, and then press
the Start Print key.)
4-4
Страница 6
4-6-2. Scanner reference position 4-6-4. Diagonal distortion
When the distance between the No. 2 scanner frame The slant caused by the optical section is adjusted
side and optical base frame’s inner wall is 89.5mm, by the No. 2 scanner pulley’s fixing position.
fix (one screw, two places) the wire rope’s caulking Note: Confirm that the diagonal distortion is not
plate so that the distance between the No. 2 scan- caused by the paper.
ner’s reference slot and No. 1 scanner’s reference
surface is 73.5mm.
Reference: When replacing the wire ropes, it is easy
o r
to adjust precisely leaving one wire rope intact
and keeping the No. 1 scanner and No. 2
scanner parallel.
Note: If this position deviates, the diagonal distortion Document Copy Copy
and focus adjustment will not be possible.
Fixing screw
73.3
Reference slot
Base slot
4-6-5. Image distortion
The image distortion caused by the optical section is Optical base frame Caulking plate
adjusted by the No. 4 and No. 5 mirror height.
Note: Do not mistake this for that caused by placing
89.5 the document at a slant.
o r
1 4-6-3. Lens reference position
Fix the timing belt (one screw) in the following state:
The lens height adjustment plate side being aligned Document Copy Copy
to the optical base frame reference position (marking
line), and No. 4 and No. 5 mirror drive cam’s refer-
ence hole and lens motor fixing frame reference hole 4-6-6. Focus
being in the same position (by inserting a fine pin). Adjust the stop position of the No. 4 and No. 5
Note: If this position is deviated, the horizontal mirrors.
magnification (lens) and focus cannot be Note: If the focus adjustment is deviated, the magni-
adjusted. fication will also be deviated. Thus, carry out
Lens motor this adjustment before the magnification Align the inner cam reference hole
fixing frame adjustment. positions and insert a pin
Stop position adjustment screw
Lens hight Height adjustment screw
adjustment plate
Timing belt fixing screw
Marking line
Marking line
MODEL MANUAL REVISED EDITION DATA PAGE METHOD
4-5
1312 SERVICE HANDBOOK 1 May.1999 4-5 REPLACEMENT
Страница 7
4-6-7. Image center position 4-7. Leading and trailing edges erase width
Adjust the lens fixing position. Adjust the leading and trailing edges erase width.
Note: This adjustment is carried out only when the 1) Procedure
corresponding section is disassembled. 1. Call out the service mode.
Normally, the adjustment is done with the (Press the Enlarge key and Reduce key for 5 sec.
document scale. in the Scale 1: 1 mode, and press the 0 key within
2 sec. after the local destination displayed)
o r
Japan US Europe
Document Copy Copy 2. Select 36 mode.
(Input 36 with the numeric keypad, and then press
1 4-6-8. Focus (Horizontal blurring) the Start Print key.)
Adjust the lens installation direction.
Note: This adjustment is carried out only when the
corresponding section is disassembled.
3. Select address (92:leading edge, 98:trailing edge). Fixing screw
(Example: Input 92 with the numeric keypad, and
One-sided blurring then press the Start Print key.)
Adjustment data
(example: 32) blinks Center
1 Code Adjustment details Adjustment range 4-6-9. Horizontal magnification
Adjust the fixing position of the sensor plate, and 92 Adjustment width:
change the lens home position. ±3mm
Note: This adjustment is carried out only when the 01 to 64
Adjustment range:
corresponding section is disassembled.
98 ±5mm
Normally, the adjustment is done with the
software (36-95).
4. Change the setting data to the required data (01 to
64:adjustment width 5mm).
o r (Input the data with the numeric keypad, and then
press the Start Print key.)
Document Copy Copy
Lens home position sensor
Sensor plate
Changed data Changed data is
Fixing screw
(example: 42) blinks set
5. When the Start Print key is pressed again, a test
copy of the settings after the changes can be
made.
6. After copying, the status will return to step 4. Thus,
if the density is not as required, repeat the
rocedure from step 4.
MODEL MANUAL REVISED EDITION DATA PAGE METHOD
4-6
1312 SERVICE HANDBOOK 1 May.1999 4-6 REPLACEMENT
Страница 8
7. When completed with the adjustment, press the
Clear/Stop key until the normal mode appears (3
pushes).
(When the Clear key is pressed once, the state
will return to the previous state.)
Note: Refer to the Chapter 8 about other adjustment
items by using the service function.
4-7