Страница 1

OUTLINE

1

ISW

2
ISW2 SERVICE

3

DIAGRAMS

4

Страница 2

ISW
ISW OUTLINE
[1] Description of the ISW [2] Operating method 1
ISW (In-System Writer) is an operation rewriting control 1. ISW connector
programs stored in the flash ROM included in the diverse The ISW connector is provided on the right side facecontrol board of a Konica digital copier with the board still of the copier. Of the two connectors situated in theinstalled in the copier main body. side face, the lower one is the ISW connector.
By implementing ISW you can update versions of control The connector for the “ISW Tool” is installed betweenprograms without changing the board or carry out the ISW connector (36-pin) and the KRDS connectormaintenance of the control board when changing the (25-pin). The cap or seal that covers each connector ISWboard. must be removed before the connector can be used.
Two ISW execution tools are prepared. One is the “ISW 2
Trns” (PC software) that implements rewriting by
connecting a personal computer (PC) and a digital copier. KRDS connector
And, the other is the specialized “ISW Tool” featuring
EPROM. These tools allow direct rewriting of the control
program in the flash ROM included in the copier main body
by connecting the ISW connector of the copier main body.

This document describes only the setup procedures
required for the 7020 series to execute the ISW. For SERVICEthe operation of the “ISW Trns” and “ISW Tool,” refer
to the “Konica ISW (In-System Writer) Instruction 3 DC5V
Manual.” jack

Caution: The “Konica ISW (In-System Writer) In-
struction Manual” describes three different ISW connector
data rewriting approaches to be
executed by the ISW Tool. Applicable ap-
proach depends on the given model of the 2. Preparing the printer for transfer
copier. As for this copier, reference the
Before operating the ISW, maintain the copier in “Type B Rewrite Operation.” standby mode until the ISW transfer is complete. DIAGRAMS

4
Step Operation procedure
1 Enter the 25 mode.
2 [25 mode screen]
Press the [11. ISW] key.
3 [ISW menu screen]
Select the ROM where the ROM data to be
rewritten.
4 [Program rewrite screen]
Pressing [START] key after [START] key is
displayed, cause the machine to be data waiting
condition.
5 Execute the operation according to the
procedures specified in the "Konica ISW
(In-System Writer) Instruction Manual."

2-1

Страница 3

ISW
OUTLINE
1 3. Types and quantity of rewrite ROM 5. Data transfer error
When rewriting the copier flash ROM data using the The FAX LED (amber) lamp lights if a transfer error
“ISW Tool,” rewriting EPROM must be prepared. occurs. If an error occurs, refer to the section "Error
handling" in the separate “ISW Service Handbook” The following table lists rewriting EPROM prepared
and perform the appropriate countermeasures. After for this machine.
the countermeasures are completed, perform the
Note: Quantity of the rewriting EPROM and rewrite operation again from the beginning.
transfer file sze are subject to change
ISW without previous notice.
2 Target control Quantity ISW trns file
program of ROM size (• bin file)
Overall control 17 Approx. 5.5 MB
Image control 2 Approx. 0.6 MB
RADF control 1 Approx. 0.1 MB
FNS control 1 Approx. 0.2 MB
FAX control 2 Approx. 0.6 MB

4. Rewrite precautions using the “ISW Tool”SERVICE Total control ROM rewrite
3 The rewrite operation must be performed to divide
the EPROM of the overall control ROM into two
groups for the 12 items indicated above. The timing
(first time data transfer end timing) for the second
time the rewrite operations is performed is as follows.
The data LED (green) of the operation part changes
from flashing to lighting.
The remaining EPROM is transferred to the “ISW
Tool” and the ROM data is transferred.DIAGRAM The LCD goes off during data transfer.
4
When data transfer is ended, the 25 mode menu
screen is displayed.
If an error occurs in the second ROM data transfer,
perform the operation again from the beginning (first
time).