Патрон-сервис. Техника и электроникаСервисный центр · Луганск
Наш телефон+7 959 128-10-50
Рабочее времяПн–пт 9:00–17:00
Сб 10:00–14:00
Патрон-сервис · Луганск

Kyocera / Mita KM1525 — сервисный документ KM1525 C-Errors

Kyocera / MitaСервисный документ4 стр.

Сервисный документ: Kyocera / Mita KM1525. Документ KM1525 C-Errors. Полный текст для поиска и оригинальный файл PDF для скачивания.

Kyocera / Mita · Сервисный документ · 4 стр. · PDF

Скачать PDF (0.0 МБ)

Ниже приведён текст исходного документа. Схемы, иллюстрации и исходное расположение таблиц сохранены в файле для скачивания.

Текст документа

Страница 1

2BV
1-5-2 Self-diagnosis

(1) Self-diagnostic function
This unit is equipped with a self-diagnostic function. When a problem is detected, copying is disabled. "C" and a number
between 011 and 740 altenates, indicating the nature of the problem.
After removing the problem, the self-diagnostic function can be reset by turning safety switch 1or 2 off and back on.

(2) Self diagnostic codes
Remarks
Code Contents
Causes Check procedures/corrective measures
C011 Backup memory data problem Defective main Replace the main PCB and check for
• Data in the specified area of the PCB. correct operation.
backup memory does not match the
specified values.
C100 Exposure lamp problem Poor contact of Check the connection of connectors CN24,
• Check the CCD input value for the the connector CN23, CN22 and CN3 on the main PCB,
lighting status of the exposure lamp terminals. and the continuity across the connector
100 ms after the exposure lamp is lit terminals. Repair or replace if necessary.
and the carriage is moved to the Defective Replace the exposure lamp or inverter shading position. If the exposure lamp exposure lamp. PCB. does not light, turn off the lamp. After
500 ms, light the lamp again and, a Defective main Replace the main PCB and check for
further 500 ms later, check the CCD PCB. correct operation.
input. Incorrect shading Adjust the position of the contact glass The exposure lamp does not light position. (shading plate). If the problem still occurs, after 5 retries. replace the scanner home position switch.
CCD PCB output Replace the ISU.
problem.
C104 Optical system problem Poor contact of Check the connection of connectors CN23,
• After AGC, correct input is not the connector CN22 and CN3 on the main PCB, and the
obtained at CCD. terminals. continuity across the connector terminals.
Repair or replace if necessary.
CCD PCB output Replace the ISU.
problem.
Defective main Replace the main PCB and check for
PCB. correct operation.
C200 Drive motor problem Poor contact of Reinsert the connector. Also check for
• LOCK ALM signal remains high for 1 the drive motor continuity within the connector cable. If
s, 1 s after the drive motor has turned connector none, repair or replace the cable.
on. terminals.

1-5-7

Страница 2

2BV

Remarks
Code Contents
Causes Check procedures/corrective measures
C200 Drive motor problem Defective drive Replace the drive motor.
• LOCK ALM signal remains high for 1 motor rotation
s, 1 s after the drive motor has turned control circuit.
on. Defective drive Check if the rollers and gears rotate
transmission smoothly. If not, grease the bushings and
system. gears. Check for broken gears and replace
if any.
C310 Scanner carriage problem Poor contact of Check the connection of connectors CN28
• The home position is not correct the connector and CN25 on the main PCB and the
when the power is turned on or at the terminals. continuity across the connector terminals.
start of copying using the contact Remedy or replace if necessary.
glass. Defective scanner Replace the scanner home position switch.
home position
switch.
Defective main Replace the main PCB and check for
PCB. correct operation.
Defective scanner Replace the scanner motor.
motor.
C400 Polygon motor synchronization Poor contact of Reinsert the connector. Also check for
problem the polygon motor continuity within the connector cable. If
• The polygon motor does not reach a connector none, repair or replace the cable.
stable speed within 19 s of the polygon terminals.
motor remote signal turning on.
C401 Polygon motor steady-state problem Poor contact of Reinsert the connector. Also check for
• The polygon motor rotation is not the polygon motor continuity within the connector cable. If
stable for 400 ms after the polygon connector none, repair or replace the cable.
motor rotation has been stabilized. terminals.
Defective power Check if 24 V DC is present at CN3-1 and
source PCB. CN3-2 on the power source PCB. If not,
replace the power source PCB.
C420 BD steady-state problem Poor contact of Reinsert the connector. Also check for
• The VTC detects a BD error for 800 the laser scanner continuity within the connector cable. If
ms after the polygon motor rotation unit connector none, repair or replace the cable.
has been stabilizad. terminals.
Defective LSU. Replace the LSU.
Defective main Replace the main PCB and check for
PCB. correct operation.
C510 Main charger problem Poor contact of Reinsert the connector. Also check for
• MC ALM signal is detected the high-voltage continuity within the connector cable. If
continuously for 800 ms when MC transformer PCB none, repair or replace the cable.
REM signal is turned on. connector
terminals.
Defective high- Replace the high-voltage transformer
voltage PCB.
transformer PCB.
Leakage during Check and clean the main charger
main charging. assembly.

1-5-8

Страница 3

2BV

Remarks
Code Contents
Causes Check procedures/corrective measures
C510 Main charger problem Deformed high- Replace the spring.
• MC ALM signal is detected voltage
continuously for 800 ms when MC transformer PCB
REM signal is turned on. terminal spring.
C610 Broken fixing heater wire Fixing heater Check and reinstall if necessary.
• Warm-up does not end within 90 s. installed
• The secondary stabilization fixing incorrectly.
temperature drops to 100°C/212°F or Broken fixing Check for continuity. If none, replace fixing below. heater wire. heater. • The fixing temperature remains below
40 ̊C/104 ̊F for 7 s or longer after the Poor contact in Check the connection of connector CN12
fixing heaters have been turned on. the fixing unit on the main PCB and the continuity across
thermistor the connector terminals. Remedy or
connector replace if necessary.
terminals.
Broken fixing unit Measure the resistance. If it is ∞ Ω, replace
thermistor wire. the fixing unit thermistor.
Fixing unit Check and reinstall if necessary.
thermistor
installed
incorrectly.
Fixing unit Check for continuity. If none, replace the
thermostat fixing unit thermostat. Check the operation
triggered. of the cooling fan and repair if necessary.
C620 Abnormally low fixing unit Fixing heater Check and reinstall if necessary.
thermistor temperature installed
• The fixing temperature remains below incorrectly.
100 ̊C/212 ̊F for 10 s during copying. Broken fixing Check for continuity. If none, replace fixing
heater wire. heater.
Poor contact in Check the connection of connector CN12
the fixing unit on the main PCB and the continuity across
thermistor the connector terminals. Remedy or
connector replace if necessary.
terminals.
Broken fixing unit Measure the resistance. If it is ∞Ω, replace
thermistor wire. the fixing unit thermistor.
Fixing unit Check and reinstall if necessary.
thermistor
installed
incorrectly.
Fixing unit Check for continuity. If none, replace the
thermostat fixing unit thermostat. Check the operation
triggered. of the cooling fan and repair if necessary.
C630 Abnormally high fixing unit Shorted fixing unit Measure the resistance. If it is 0 Ω, replace
thermistor temperature thermistor. the fixing unit thermistor.
• The fixing temperature exceeds Broken fixing Replace the power source PCB. 240 ̊C/464 ̊F for 10 s. heater control
circuit on the
power source PCB.

1-5-9

Страница 4

2BV

Remarks
Code Contents
Causes Check procedures/corrective measures
C710 Toner sensor problem Defective toner Replace the toner sensor.
• The sensor output voltage is outside sensor.
the range of 0.5 to 4.5 V during toner Poor contact of Reinsert the connector. Also check for control. the toner sensor continuity within the connector cable. If • The toner sensor control voltage connector none, repair or replace the cable. cannot be set within the setting range terminals. when maintenance item U130 is run.
Developer Replace the developer.
problem.
C730 Broken external temperature Poor contact of Reinsert the connector. Also check for
thermistor wire the humidity continuity within the connector cable. If
• The input voltage is above 4.5 V. sensor PCB none, repair or replace the cable.
connector
terminals.
Defective external Replace the humidity sensor PCB.
temperature
thermistor.
C731 Short-circuited external temperature Poor contact of Reinsert the connector. Also check for
thermistor the humidity continuity within the connector cable. If
• The input voltage is below 0.5 V. sensor PCB none, repair or replace the cable.
connector
terminals.
Defective external Replace the humidity sensor PCB.
temperature
thermistor.
C740 Image formation unit connector Image formation Reinsert the image formation unit
insertion problem unit connector connector if necessary.
• Absence of the image formation unit inserted
is detected continuously for 1500 ms incorrectly.
while there is no error on the copier. Defective image Replace the image formation unit.
formation unit
connector.

1-5-10

График работыПн–пт 9:00–17:00
Сб 10:00–14:00
Напишите на почтуmail@patronlg.ru
Ждём вас в мастерскойЛуганск, ул. Газеты
Луганская Правда, 153В
Позвонить в Патрон-сервис
Заказать звонок
+
Жду звонка!