(1) Copier is not energized at all.
Relevant Electrical Parts
IO Board (PWB-IO) DC Power Supply 1 (PU1)
DC Power Supply 2 (PU2)
WIRING
Step Check Item DIAGRAM Result Action
(Location)
Check wiring Is a power voltage supplied across 1 30-H NO between the wall PJ3PU1-1 and 3 on PU1? outlet and PJ3PU1.
Are the fuses (F1 and F2) on PU1 con- 2 — NO Change PU1. ducting?
Is a power voltage supplied across 3 30-F NO Change PU1. CN1PU2-1 and 2 on PU2?
4 Is the fuse (F1) on PU2 conducting? — NO Change PU2.
Is DC5 V being output from CN2PU2-3 5 31-F NO Change PU2. on PU2?
Is DC5 V being input to PJ15PU1-1 on 6 28-F NO Change PU2. PU1?
Is DC5 V being input to PJ1IO-3 on the NO Change PU1. 7 14-E
IO Board? YES Change PWB-IO.
Страница 2
Relevant Electrical Parts
PIC Board (PWB-PIC) DC Power Supply 1 (PU1)
DC Power Supply 2 (PU2)
WIRING
Step Check Item DIAGRAM Result Action
(Location)
Is DC3.3 V being output from PJ9PU1-1 1 29-F NO Change PU1. on PU1?
Is DC5 V being output from CN2PU2-2 2 31-F NO Change PU2. on PU2?
Is DC3.3 V being input to PJ1PIC-1 on YES Change PWB-PIC. 3 32-C
PWB-PIC and DC5 V to PJ1PIC-3? NO Check the wiring.
(3) Control panel indicators do not light.
Relevant Electrical Parts
Image Processing Board (PWB-C) DC Power Supply 3 (PU201)
Control Panel (UN201)
WIRING
Step Check Item DIAGRAM Result Action
(Location)
Reconnect or Is the I/F cable between the IR and 1 — NO change the I/F engine connected properly? cable.
Check the wiring Is a power voltage being applied across 2 22-H NO from the wall outlet CN3PU201-1 and 2 on PU201? to CN3PU201-1/2.
3 Is the fuse (F1) on PU201 conducting? — NO Change PU201.
Is DC5.1 V being output from
4 CN2PU201-1 on PU201 and DC24 V 22-H NO Change PU201.
from CN2PU201-3?
Is PJ12C on PWB-C securely con- 5 26-E NO Reconnect. nected?
NO Reconnect.
Is CN12 on UN201 securely con-
6 24-F Change UN201. nected? YES Change PWB-C.