Сервисный документ: Minolta CF3101. Документ Trouble Code_E. Полный текст для поиска и оригинальный файл PDF для скачивания.
Minolta · Сервисный документ · 7 стр. · PDF
Ниже приведён текст исходного документа. Схемы, иллюстрации и исходное расположение таблиц сохранены в файле для скачивания.
Переход к странице документа
Текст документа
Страница 1
Warning
Item Timing
Code
• The output from the photoreceiver of the AIDC Sensor
that takes a reading of a point of a bare surface on the
Transfer Belt is 4.5 V or more during an adjustment of the
AIDC Sensor.
P-5 AIDC Sensor (Front) failure • The output from the photoreceiver of the AIDC Sensor
that takes a reading of a point in a toner pattern on the
Transfer Belt is 1.0 V or less after the adjustment has
been completed.
P-6 Cyan IU failure
All density readings taken from the density pattern pro-
P-7 Magenta IU failure duced on the Transfer Belt are 0.4 V (AIDC Sensor photore-
P-8 Yellow IU failure ceiver output) or less during max. density adjustment (Vg/
Vb adjustment)
P-9 Black IU failure
• The number of points detected in the CD direction is
more or less than the specified value during CD registra-
tion correction.
P-21 Color Shift Test Pattern failure • The number of points detected in the FD direction is more
or less than the specified value during FD registration
correction.
• The color shift amount is greater than the specified range
during CD registration correction.
• The color shift amount is greater than the specified range
P-22 Color Shift Adjust failure
during FD registration correction.
• The skew correction amount is greater than the specified
value.
P-23 ATVC(C) failure
P-24 ATVC(M) failure An abnormal average value is detected during an adjust-
P-25 ATVC(Y) failure ment of the first image transfer ATVC value of each color.
P-26 ATVC(Bk) failure
An abnormal average value is detected during an adjust-
P-27 ATVC(2nd) failure
ment of the second image transfer ATVC value.
• The output from the photoreceiver of the AIDC Sensor
that takes a reading of a point of a bare surface on the
Transfer Belt is 4.5 V or more during an adjustment of the
AIDC Sensor.
P-28 AIDC Sensor (Back) failure • The output from the photoreceiver of the AIDC Sensor
that takes a reading of a point in a toner pattern on the
Transfer Belt is 1.0 V or less after the adjustment has
been completed.
Страница 2
Malfunction
Item Timing
Code
The Main Motor Lock signal remains HIGH for a predeter-
C0000 Main Motor’s failure to turn mined continuous period of time while the Main Motor is
turning.
The Main Motor Lock signal remains LOW for a predeter-
Main Motor Turning at
C0001 mined continuous period of time while the Main Motor
abnormal timing
remains stationary.
The Imaging Unit Motor C Lock signal remains HIGH for a
Imaging Unit Motor C’s
C0010 predetermined continuous period of time while the Imaging
failure to turn
Unit Motor C is turning.
The Imaging Unit Motor C Lock signal remains LOW for a
Imaging Unit C turning at
C0011 predetermined continuous period of time while the Imaging
abnormal timing
Unit Motor C remains stationary.
The Imaging Unit Motor M Lock signal remains HIGH for a
Imaging Unit Motor M’s
C0012 predetermined continuous period of time while the Imaging
failure to turn
Unit Motor M is turning.
The Imaging Unit Motor M Lock signal remains LOW for a
Imaging Unit M turning at
C0013 predetermined continuous period of time while the Imaging
abnormal timing
Unit Motor M remains stationary.
The Imaging Unit Motor Y Lock signal remains HIGH for a
Imaging Unit Motor Y’s
C0014 predetermined continuous period of time while the Imaging
failure to turn
Unit Motor Y is turning.
The Imaging Unit Motor Y Lock signal remains LOW for a
Imaging Unit Y turning at
C0015 predetermined continuous period of time while the Imaging
abnormal timing
Unit Motor Y remains stationary.
The Imaging Unit Motor Bk Lock signal remains HIGH for a
Imaging Unit Motor Bk’s
C0016 predetermined continuous period of time while the Imaging
failure to turn
Unit Motor Bk is turning.
The Imaging Unit Motor Bk Lock signal remains LOW for a
Imaging Unit Bk turning at
C0017 predetermined continuous period of time while the Imaging
abnormal timing
Unit Motor Bk remains stationary.
The Fan Lock signal remains HIGH for a predetermined
Suction Fan Motor’s
C0040 continuous period of time while the Suction Fan Motor is
failure to turn
turning.
The Fan Lock signal remains HIGH for a predetermined
Cooling Fan Motor 1’s
C0043 continuous period of time while the Cooling Fan Motor 1 is
failure to turn
turning.
The Fan Lock signal remains HIGH for a predetermined
Cooling Fan Motor 3’s
C0044 continuous period of time while the Cooling Fan Motor 3 is
failure to turn
turning.
The Fan Lock signal remains HIGH for a predetermined
Cooling Fan Motor 4/5’s
C0045 continuous period of time while the Cooling Fan Motor 4/5 is
failure to turn
turning.
The Fan Lock signal remains HIGH for a predetermined
Fusing Cooling Fan Motor’s
C0046 continuous period of time while the Fusing Cooling Fan
failure to turn
Motor is turning.
Страница 3
Ozone Ventilation Fan
C004C continuous period of time while the Ozone Ventilation Fan
Motor’s failure to turn
Motor is turning.
The Fan Lock signal remains HIGH for a predetermined
Power Supply Cooling
C004E continuous period of time while the Power Supply Cooling
Fan Motor’s failure to turn
Fan Motor is turning.
The Fan Lock signal remains HIGH for a predetermined
Cooling Fan Motor 2’s
C004F continuous period of time while the Cooling Fan Motor 2 is
failure to turn
turning.
The Fusing Drive Motor Lock signal remains HIGH for a pre-
Fusing Drive Motor’s
C0060 determined continuous period of time while the Fusing
failure to turn
Drive Motor is turning.
The Fusing Drive Motor Lock signal remains LOW for a pre-
Fusing Drive Motor turning
C0061 determined continuous period of time while the Fusing
at abnormal timing
Drive Motor remains stationary.
• The 2nd Image Transfer Pressure Position Sensor is not
activated (retracted position) within 2 sec. after the 2nd
Image Transfer Pressure/Retraction Motor has started
turning during a sequence of the 2nd Image Transfer
2nd Image Transfer Roller Roller's retracting motion.
C0094
pressure/retraction failure • The 2nd Image Transfer Pressure Position Sensor is not
deactivated (pressed position) within 2 sec. after the 2nd
Image Transfer Pressure/Retraction Motor has started
turning during a sequence of the 2nd Image Transfer
Roller's pressing motion.
• The 1st Image Transfer Retraction Position Sensor is not
activated (retracted position) within 3 sec. after the 1st
Image Transfer Pressure/Retraction Motor has started
turning during a sequence of the Transfer Belt's retracting
Image Transfer Belt motion.
C0096
pressure/retraction failure • The 1st Image Transfer Retraction Position Sensor is not
deactivated (pressed position) within 1 sec. after the 1st
Image Transfer Pressure/Retraction Motor has started
turning during a sequence of the Transfer Belt's pressing
motion.
• No change is observed in the encoder pulse of the Fusing
Pressure/Retraction Motor even after the lapse of 0.5 sec.
after the motor has started turning for a sequence of the
Fusing Pressure Roller's retracting motion.
• No change is observed in the encoder pulse of the Fusing
Pressure/Retraction Motor even after the lapse of 0.5 sec.
Fusing Pressure Roller
C0098 after the motor has started turning for a sequence of the
pressure/retraction failure
Fusing Pressure Roller's pressing motion.
• The Fusing Pressure Position Sensor is not activated
(pressed position) even when 21 encoder pulses of the
Fusing Pressure/Retraction Motor are counted after the
motor has started turning for a sequence of the Fusing
Pressure Roller's pressing motion.
The SCD signal is detected for a continuous 0.7-sec. period
Cyan PC Drum Charge when the Cyan PC Drum Charge Corona is automatically
C0200
Corona malfunction energized as the malfunction is reset after C0208 (PC Drum
Charge Corona malfunction) has been detected.
Страница 4
Magenta PC Drum Charge when the Magenta PC Drum Charge Corona is automati-
C0202
Corona malfunction cally energized as the malfunction is reset after C0208 (PC
Drum Charge Corona malfunction) has been detected.
The SCD signal is detected for a continuous 0.7-sec. period
Yellow PC Drum Charge when the Yellow PC Drum Charge Corona is automatically
C0204
Corona malfunction energized as the malfunction is reset after C0208 (PC Drum
Charge Corona malfunction) has been detected.
The SCD signal is detected for a continuous 0.7-sec. period
Black PC Drum Charge when the Black PC Drum Charge Corona is automatically
C0206
Corona malfunction energized as the malfunction is reset after C0208 (PC Drum
Charge Corona malfunction) has been detected.
PC Drum Charge Corona The SCD signal is detected for a continuous 0.7-sec. period
C0208
malfunction while the PC Drum Charge Corona is being energized.
Exposure Lamp’s The output from the CCD Sensor is a predetermined value
C0400
failure to turn ON or less during CCD Sensor gain adjustment.
The average output value of the CCD Sensor with the Scan-
Exposure Lamp turning ON
C0410 ner at its standby position is a predetermined value or more
at abnormal timing
at the end of a scan job.
• The Heating Roller Thermistor does not detect a prede-
termined temperature within 550 sec. after a warm-up
cycle has been started and thus the copier does not com-
Heating Roller warm-up
C0500 plete the warm-up cycle.
failure • The output from the Heating Roller Thermistor does not
rise beyond a predetermined level within 30 sec. after the
Heating Roller Heater Lamps have lit up.
• The temperature detected by the Fusing Pressure Roller
Thermistor does not reach 100 °C within 230 sec. after a
Fusing Pressure Roller warm-up cycle has been started.C0501
warm-up failure • The output from the Heating Roller Thermistor does not
rise beyond a predetermined level within 120 sec. after
the Fusing Pressure Roller Heater Lamp has lit up.
• The Heating Roller Thermistor detects 160 °C or less for
1 sec. or more while the copier is in the standby state.
• The Heating Roller Thermistor detects 160 °C or less for Heating Roller abnormally
C0510 low temperature 1 sec. or more while the copier is in a print cycle.
• The Heating Roller Thermistor detects 70 °C or less for 1
sec. or more while the copier is in the Energy Saver
mode.
• The Fusing Pressure Roller Thermistor detects 100 °C or
less for 1 sec. or more while the copier is in the standby
state.
Fusing Pressure Roller • The Fusing Pressure Roller Thermistor detects 100 °C orC0511 abnormally low
less for 1 sec. or more while the copier is in a print cycle. temperature
• The Fusing Pressure Roller Thermistor detects 100 °C or
less for 1 sec. or more while the copier is in the Energy
Saver mode.
Heating Roller abnormally The Heating Roller Thermistor detects 220 °C or more for 1C0520
high temperature sec. or more.
Страница 5
more for 1 sec. or more. temperature
• The Scanner Home Sensor is unable to detect a Scanner
when the Scanner is at a position to block the sensor.
• The Scanner Home Sensor is unable to detect a Scanner
despite the fact that the Scanner Motor has been ener-
Scanner Home Sensor
C0650 gized to move the Scanner over the maximum traveling
malfunction
distance.
• The Scanner Home Sensor detects a Scanner when the
Scanner has moved a distance of 5 mm away from the
position, at which it blocks the sensor.
The Scanner Home Sensor detects the Scanner at its home
position during a period of time that begins with the time
C0660 Scanner overrun failure when a prescan command and a scan preparation com-
mand are executed and ends when a home return com-
mand is executed.
Toner density that is 3% or more lower than the target level
Abnormally low toner
is detected ten consecutive times while the Developing Unit
C0F30 density detected
is being energized during a print cycle, ATVC, or image sta-
Cyan ATDC Sensor
bilization sequence.
Toner density that is 4% or more higher than the target level
Abnormally high toner
is detected ten consecutive times while the Developing Unit
C0F31 density detected
is being energized during a print cycle, ATVC, or image sta-
Cyan ATDC Sensor
bilization sequence.
Toner density that is 3% or more lower than the target level
Abnormally low toner
is detected ten consecutive times while the Developing Unit
C0F32 density detected
is being energized during a print cycle, ATVC, or image sta-
Magenta ATDC Sensor
bilization sequence.
Toner density that is 4% or more higher than the target level
Abnormally high toner
is detected ten consecutive times while the Developing Unit
C0F33 density detected
is being energized during a print cycle, ATVC, or image sta-
Magenta ATDC Sensor
bilization sequence.
Toner density that is 3% or more lower than the target level
Abnormally low toner
is detected ten consecutive times while the Developing Unit
C0F34 density detected
is being energized during a print cycle, ATVC, or image sta-
Yellow ATDC Sensor
bilization sequence.
Toner density that is 4% or more higher than the target level
Abnormally high toner
is detected ten consecutive times while the Developing Unit
C0F35 density detected
is being energized during a print cycle, ATVC, or image sta-
Yellow ATDC Sensor
bilization sequence.
Toner density that is 3% or more lower than the target level
Abnormally low toner
is detected ten consecutive times while the Developing Unit
C0F36 density detected
is being energized during a print cycle, ATVC, or image sta-
Cyan ATDC Sensor
bilization sequence.
Toner density that is 4% or more higher than the target level
Abnormally high toner
is detected ten consecutive times while the Developing Unit
C0F37 density detected
is being energized during a print cycle, ATVC, or image sta-
Cyan ATDC Sensor
bilization sequence.
Cyan ATDC Sensor Cyan ATDC Sensor automatic adjustment does not function
C0F3A
adjustment failure properly, failing to adjust to an appropriate value.
Magenta ATDC Sensor Magenta ATDC Sensor automatic adjustment does not
C0F3B
adjustment failure function properly, failing to adjust to an appropriate value.
Страница 6
C0F3C
adjustment failure tion properly, failing to adjust to an appropriate value.
Black ATDC Sensor Black ATDC Sensor automatic adjustment does not function
C0F3D
adjustment failure properly, failing to adjust to an appropriate value.
The WORK memory or Controller Board are not mounted
Memory mounting
C1200 on the Image Control Board (PWB-F) when the printer con-
failure
troller Fiery X3e 31C-M is installed.
Memory mounting The FILE memory on the Image Control Board (PWB-F) is
C1203
failure faulty.
Memory mounting The FILE memory on the Image Control Board (PWB-F) is
C1204
failure short of capacity
Image Input Image data is not input from the Image Processing Board
C1220
Time Out (PWB-C) to the Image Control Board (PWB-F).
Image Output Image data is not output from the Image Control Board
C1229
Time Out (PWB-F) to the PIC Board (PWB-PIC).
C1240 JBIG Error
C1241 JBIG Error
Memory of the Image Control Board (PWB-F) is faulty.
C1242 JBIG Error
C1243 JBIG Error
Memory Board Compression of image data of the Image Control Board
C1261
Time Out (PWB-F) is faulty.
Memory Board Decompression of image data of the Image Control Board
C1265
Time Out (PWB-F) is faulty.
Memory Board Transfer of image data of the Image Control Board (PWB-F)
C1279
Time Out is faulty.
Compression/decompression of image data of the Image
Compress/Expand
C1290 Control Board (PWB-F) is faulty when the print controller
Time Out
IP-711 is mounted.
Unable to communicate between the hard disk and Image
C12C0 Hard Disk Error
Control Board (PWB-F).
C12CB Hard Disk Error Data transfer from the hard disk is faulty.
C12CC Hard Disk Error Unformatted hard disk is connected.
C12C1 Hard Disk Error
C12C2 Hard Disk Error
C12C3 Hard Disk Error
C12C4 Hard Disk Error
C12C5 Hard Disk Error
Hard disk is faulty.
C12C6 Hard Disk Error
C12C7 Hard Disk Error
C12C8 Hard Disk Error
C12C9 Hard Disk Error
C12CA Hard Disk Error
A hard disk that falls outside the specifications is con-
C12CF Hard Disk Error
nected.
New Transfer Cleaner Unit A new installation is not canceled when a new Transfer
C13C8
resetting failure Cleaner Unit (Image Transfer Belt Unit) is installed.
Страница 7
C13CA
resetting failure installed.
Setting 1 “Start Flag” of GA register does not become ready
Cyan IU EEPROM
C13D1 even after the lapse of a predetermined period of time after
access error
a cyan IU EEPROM access control has been executed.
Setting 1 “Start Flag” of GA register does not become ready
Magenta IU EEPROM
C13D2 even after the lapse of a predetermined period of time after
access error
a magenta IU EEPROM access control has been executed.
Setting 1 “Start Flag” of GA register does not become ready
Yellow IU EEPROM
C13D3 even after the lapse of a predetermined period of time after
access error
a yellow IU EEPROM access control has been executed.
Setting 1 “Start Flag” of GA register does not become ready
Black IU EEPROM
C13D4 even after the lapse of a predetermined period of time after
access error
a black IU EEPROM access control has been executed.
A fault occurs while the LPH correction data is being down-
Cyan LPH correction data
C13D5 loaded from the Cyan LPH EEPROM to the flash memory
download failure
on PWB-PIC when power is turned ON.
A fault occurs while the LPH correction data is being down-
Magenta LPH correction
C13D6 loaded from the Magenta LPH EEPROM to the flash mem-
data download failure
ory on PWB-PIC when power is turned ON.
A fault occurs while the LPH correction data is being down-
Black LPH correction data
C13D7 loaded from the Yellow LPH EEPROM to the flash memory
download failure
on PWB-PIC when power is turned ON.
A fault occurs while the LPH correction data is being down-
Black LPH correction data
C13D8 loaded from the Black LPH EEPROM to the flash memory
download failure
on PWB-PIC when power is turned ON.
• The adjustment value is 0 or 255 during a CCD clamp
CCD clamp/gain adjustment.
C3310
adjustment failure • The peak value of the output data is 64 or less during a
CCD gain adjustment.
IR Power Supply
C3700 Cooling Fan Motor turning A Lock signal is detected ten consecutive times when it is
at abnormal timing monitored at 0.01-sec. intervals during a period of time 2
IR Drive Board sec. after the output of a Fan Motor ON signal has been
C3710 Cooling Fan Motor turning started.
at abnormal timing
ROM contents fault A fault is detected in the contents of ROM of MSC, IR, and
C3FFF
detected upon start PRT when the copier is started.