Технический бюллетень: Ricoh FT 4215 / 4220. Документ R_FT4220. Полный текст для поиска и оригинальный файл PDF для скачивания.
Ricoh · Технический бюллетень · 24 стр. · PDF
Ниже приведён текст исходного документа. Схемы, иллюстрации и исходное расположение таблиц сохранены в файле для скачивания.
Переход к странице документа
Текст документа
Страница 1
SUBJECT: Service Manual Correction DATE: Aug. 15, ’93
PAGE: 1 of 1
PREPARED BY: S. Orita FROM: Copier Technical Support Section
CHECKED BY:
CLASSIFICATION: MODEL:
Action Required Revision of service manual Pigeon A (A110) and B
Troubleshooting Information only (A111)
Retrofit Information Other
Please correct your service manual as follows:
1. Page 4-14
Incorrect
Mode No. Function Data
°20 APS Priority Specifies whether the copier defaults to APS 0: APS
(Copier) or manual mode when the main switch is 1: Manual
turned on.
This mode is used only on the A111 copier.
Correct
Mode No. Function Data
°20 APS Priority Specifies whether the copier defaults to 0: APS
(Copier) APS or manual mode when the main switch 1: Manual
is turned on.
For A110 copiers, the default is "1". Do not
change the data to "0".
For A111 copiers, the default is "0".
Страница 2
SUBJECT: APS Priority with ADF (Pigeon A only) DATE: Aug. 15, ’93
PAGE: 1 of 3
PREPARED BY: S. Orita FROM: Copier Technical Support Section
CHECKED BY:
CLASSIFICATION: MODEL:
Action Required Revision of service manual Pigeon A (A110)
Troubleshooting Information only
Retrofit Information Other
[Phenomenon] The copier will not select APS automatically with ADF when the
original is set on the ADF, although the data of SP21 (APS priority for
ADF) is set to "0" (0: APS, 1: Manual).
Note: This problem occurs only on A110 copiers (Pigeon A)
with ADF. It does not occur on A111 copiers (Pigeon B).
[Cause] Software problem for SP21 and SP72. (Refer to the table below.)
[Solution] To solve this problem, the ROM has been changed from P/N
A1115107 to P/N A1115107A.
The functions of SP21 and SP72 for each ROM are as follows:
SP Mode No. P/N A1115107 P/N A1115107A
20 APS Priority The default is "0". (0: APS, 1: The default is "0" and the
(Copier) Manual) factory setting is "1".
When the main switch is The data does not change
turned on, the data will although the main switch is
automatically change to "1" turned on.
although the data is set to "0".
21 APS Priority When the main switch is The data does not change
(ADF) turned on, the data will although the main switch is
automatically change to "1" turned on.
although the data is set to "0".
(0: APS, 1: Manual)
72 For A110 copiers, the default Same as P/N A1115107.
is "1". (0: Normal, 1: APS
disabled)
Страница 3
SUBJECT: APS Priority with ADF (Pigeon A only) DATE: Aug. 15, ’93
PAGE: 2 of 3
According to this change, the following procedure is required only when the ADF is
installed on A110 copiers.
a: For machines which have the old ROM (P/N A1115107).
1) Replace the old ROM with the new one (P/N A1115107A)
2) Change the data of SP21 from "1" to "0".
3) Change the data of SP72 from "1" to "0".
4) Confirm that the data of SP20 is "1".
b: For machines which have the new ROM (P/N A1115107A).
1) Change the data of SP72 from "1" to "0".
2) Confirm that the data of SP20 is "1" and the data of SP21 is "0".
Note: If SP99 (Clear All Memory) is performed, change the data of SP20 from "0" to
"1", and the data of SP72 from "1" to "0".
The cut-in serial numbers for the new ROM (A1115107A) are as follows:
Machine Code Cut-in Serial Number
A110-10 From First Production
A110-15 From First Production
A110-17 From First Production
A110-19 From First Production
A110-22 From First Production
A110-26 From First Production
A110-27 A3473070041
A110-29 From First Production
To ease the installation procedure for the ADF, the functions of SP21 and SP72 for the
ROM will be further changed. The suffix of the part number will be changed from
A1115107A to A1115107B as follows:
SP Mode No. P/N A1115107B
20 APS Priority For A110 copiers, the default and the
(Copier) factory setting are "1" (Manual).
72 The default is "0" (Normal).
For machines which have the new ROM (P/N A1115107B), it is not necessary to change
the data of SP21 and SP72 when the ADF is installed on A110 copier. Even if SP99
(Clear All Memory) is performed, it is not necessary to change the data of SP20 and SP72.
Страница 4
SUBJECT: APS Priority with ADF (Pigeon A only) DATE: Aug. 15, ’93
PAGE: 3 of 3
Note: 1. For machines which have an old ROM (P/N A1115107 or A1115107A)
When the data of SP72 is set to "0", APS is enabled.
Therefore, when the ADF is installed, the data of SP72 should be set to "0".
When the ADF is not installed, the data of SP72 should be set to "1".
2. For machines which have the new ROM (P/N A1115107B)
APS is disabled when the ADF is not installed even if the data of SP72 is set
to "0".
The machine automatically selects the APS based on the signal from the ADF
when the original is set on the ADF.
Страница 5
SUBJECT: Service Manual Correction DATE:
PAGE: 1 of 4
PREPARED BY: J. Kasamoto FROM: Copier Technical Support Section
CHECKED BY:
CLASSIFICATION: MODEL: Pigeon A and B
Action Required Revision of service manual
Troubleshooting Information only
Retrofit Information Other
Some mistakes were found in the manual. Please correct your manuals as follows:
1. Page 5-39
The Entrance Seal Replacement procedure should be changed as follows:
4.7 ENTRANCE SEAL REPLACEMENT
[B] 4.5±0.5mm
[A]
[C]
[J]
[F]
[J]
1±1mm [D] [E] 4±1mm [I] 4±1mm
[C] [G] [H]
1. Remove the cleaning unit and the following parts:
• Cleaning Blade
• Cleaning Brush
2. Remove the used toner. (See Used Toner Collection.)
3. Clean the cleaning unit with a vacuum cleaner.
4. Remove the entrance seal [A] together with the strip of 2 sided tape securing it to the
lower casing.
Страница 6
SUBJECT: Service Manual Correction DATE:
PAGE: 2 of 4
5. Clean the lower casing [B] with alcohol: make sure that no tape remains on the casing
surface.
6. Place a new strip of 2-sided tape [C] on the lower casing surface as shown in the
illustration. The upper edge [D] of the tape must be flush with the edge [E] of the
projection as shown in the illustration.
7. Place the new entrance seal [F] on the 2-sided tape as shown in the illustration.
NOTE: a) The lower edge [G] of the entrance seal must be aligned with the edge [H] of
the lower casing.
b) Make sure that there are no waves in the upper edge [I] of the entrance seal.
8. Place the new side seals [J] on the entrance seal as shown. Bend and stick the trail
edge of the seal to the bottom casing.
2. Page 5-80 and 81
• The spacer illustrated in the Hot Roller Replacement procedure has been eliminated from
the mass-production units.
• The gear (P/N AB013201) on the hot roller shaft was illustrated incorrectly. The illustra-
tion should show the gear’s boss facing out.
For the reasons above, please replace the information on pages 5-80 and 5-81 of your
service manuals with the following:
Страница 7
SUBJECT: Service Manual Correction DATE:
PAGE: 3 of 4
7.4 HOT ROLLER REPLACEMENT
[A]
[C]
[E]
[F] [D]
[B] [G]
[I]
[H]
[A]
1. Remove the exit unit. (See Exit Unit Removal.)
2. Remove the fusing lamp. (See Fusing Lamp Replacement.)
3. If the duplex tray is installed, remove the turn guide plate (2 screws).
4. Remove the exit paper guide (1 screw).
5. Remove the front and rear pressure springs [A].
6. Remove the C-ring [B] (front side).
7. Remove the 2 screws [C] securing the bearing to the fusing front frame, then remove
the bearing [D] and spacer [E].
8. Remove the rear C-ring [F].
9. Slide the hot roller out. The gear [G] will drop off the hot roller shaft.
10. Replace the hot roller [H] (1 bearing [I]).
Страница 8
SUBJECT: Service Manual Correction DATE:
PAGE: 4 of 4
[D]
[B]
[A]
[C]
– Reinstallation –
1. Set the rear bearing [A] on the rear frame.
2. Insert the rear end of the hot roller shaft through the rear bearing.
3. Place the gear [B] on the rear end of the shaft.
NOTE: The gear’s flange must face out.
4. Install the front bearing and spacer, then secure with two screws [C].
5. Set the rear side C-ring [D] on the rear shaft.
NOTE: a) Peel off 3 cm (1 inch) from both ends of the protective sheet before installing
a new hot roller.
b) Before setting the pressure springs, remove the rest of the protective sheet.
c) Before reinstalling the pressure springs, refer to the installation procedure in
the Pressure Roller Replacement Section.
Страница 9
SUBJECT: Service manual correction DATE:
January 31, 1994
PAGE: 1 of 2
PREPARED BY: S. Orita FROM: 2nd Technical Support Section
CHECKED BY:
CLASSIFICATION: MODEL:
Action Required Revision of service manual Pigeon A (A110)
Troubleshooting Information only and B (A111)
Retrofit Information Other
Please correct your service manual as follows:
1. Page 1-2
Incorrect
Power Consumption:
A110 Copier A111 Copier
Maximum 1.2 kVA 1.3 kVA
Warm-up 720 VA (average) 720 VA (average)
Copy cycle 810 VA (average) 830 VA (average)
Stand-by (Without 160 VA (average) 160 VA (average)
energy saver function)
Correct
Power Consumption
A110 Copier A111 Copier
Copier only Full system Copier only Full system
Maximum 1.2 kVA 1.5 kVA 1.3 kVA 1.5 kVA
Warm-up 800 VA 800 VA 800 VA 800 VA
(average) (average) (average) (average)
Copy cycle 900 VA 800 VA 900 VA 800 VA
(average) (average) (average) (average)
Stand-by 180 VA 180 VA 180 VA 180 VA
(Without (average) (average) (average) (average)
energy saver
function)
Страница 10
SUBJECT: Service Manual Correnction DATE:
January. 31, 1994
PAGE: 2 of 2
2. Page 4-15
Incorrect
Mode No. Function Data
°34 ADS Level Selects the image density level in 0: Normal
ADS mode. 1 Darker
Data: 1 2: Lighter
Decreases development bias
voltage (+ 40V).
Exposure lamp data is not changed.
Data: 2
Increases exposure lamp data (+ 2)
Development bias voltage is not
changed.
Correct
Mode No. Function Data
°34 ADS Level Selects the image density level in 0: Normal
ADS mode. 1 Darker
Data: 1 2: Lighter
Decreases development bias
voltage (+ 40V).
Exposure lamp data is not changed.
Data: 2
Increases exposure lamp data (+ 4)
Development bias voltage is not
changed.
Страница 11
SUBJECT: Service Manual Correction DATE:
April 30, 1994
PAGE: 1 of 2
PREPARED BY: S. Orita FROM: 2nd Technical Support Section
CHECKED BY:
CLASSIFICATION: MODEL:
Action Required Revision of service manual Pigeon A and B
Troubleshooting Information only (A110/A111)
Retrofit Information Other
Please correct your service manual as follows:
1. Page 2-20 (VL Correction Factor)
Incorrect
SP data (SP61) Change of exposure lamp data/Machine on time
0 +1/70H
1 +1/140H
2 +1/40H
3 +1/20H
4 +1/10H
5 +1/5H
6 No correction
Correct
SP data (SP61) Change of exposure lamp data/Machine on time
0 +1/70H
1 +1/20H
2 +1/40H
3 +1/140H
4 +1/10H
5 +1/5H
6 No correction
Страница 12
SUBJECT: Service Manual Correction DATE:
April. 30, 1994
PAGE: 2 of 2
2. Page 4-17
Incorrect
Mode No. Function Data
61 VL Correction Sets the interval of VL correction. 0: every 70 hours
Interval The exposure lamp data increases 1: every 140 hours
by +1 at set interval of machine on 2: every 40 hours
time. 3: every 20 hours
Do not change the data more than 4: every 10 hours
one (1) step at a time. 5: every 5 hours
6: No correction
Correct
Mode No. Function Data
61 VL Correction Sets the interval of VL correction. 0: every 70 hours
Interval The exposure lamp data increases 1: every 20 hours
by +1 at set interval of machine on 2: every 40 hours
time. 3: every 140 hours
Do not change the data more than 4: every 10 hours
one (1) step at a time. 5: every 5 hours
6: No correction
Страница 13
SUBJECT: Software Modification DATE:
May 15, 1994
PAGE: 1 of 5
PREPARED BY: S. Orita FROM: 2nd Technical Support Section
CHECKED BY:
CLASSIFICATION: MODEL:
Action Required Revision of service manual Pigeon A and B
Troubleshooting Information only (A110/A111)
Retrofit Information Other
Because of software changes, the ROM has been changed from A1115107C to P/N
A1115107D.
The details of software changes are as follows:
1. "Add Toner" indicator stays on
[Phenomenon]
"Add Toner" indicator stays on although toner is in the cartridge.
[Cause]
According to tolerance of toner characteristics, toner may get high electrical potential when
it is agitated with developer. If toner with high electrical potential is mixed in developer, the
density of ID sensor pattern on the drum becomes low. This results in high toner density in
the development unit. Under this condition, a larger amount of toner physically adheres to
the non-image areas of the drum surface. That results in low Vsg. When the Vsg becomes
around 2.5 volts, the main CPU will improperly detect toner end condition.
[Solution]
To reduce the toner density in the development unit, the black development bias voltage
for the ID sensor pattern (SP33) has been decreased as follows:
Development bias voltage Toner Density SP data (SP33)
Old New
Normal 0 –280 volts –240 volts
Low 1 –240 volts –200 volts
High 2 –300 volts –260 volts
Higher 3 –320 volts –280 volts
Lower 4 –200 volts –180 volts
Highest 5 –340 volts –300 volts
Страница 14
SUBJECT: Software modification DATE:
May 15, 1994
PAGE: 2 of 5
[Action Required]
The following procedure is required when this problem occurs on the field machines with
old ROM (P/N A1115107, A, B or C)
(To clear the toner end condition)
1. Remove the rear cover and disconnect the toner supply clutch connector from the main
board (CN118).
2. Open and close the front cover to perform the toner end recovery.
3. Repeat step 2 until the Start key turns green.
4. If the Start key will not turn green by step 3, replace the developer.
(To prevent this problem from occurring again)
1. Clean the drum area and optics section.
2. Clear the VL correction by SP94.
3. Enter SP33 and set the data to "1".
4. Enter SP62 and increase the data by +2 from "SP Mode Factory Setting Data".
5. If the color development unit is installed, enter SP75 and set the data to "3".
6. Make sky shot copies to reduce the toner density until SP55 shows Vsp between 0.40
volts and 0.70 volts.
7. Check if Vsg is higher than 3.5 volts in SP55.
8. Adjust the copy image by SP48 and SP56.
Страница 15
SUBJECT: Software modification DATE:
May 15, 1994
PAGE: 3 of 5
NOTE: Do not perform SP99 except in an emergency case. However, if you feel that it is
costly or/and not easy to replace the developer in order to clear the toner end
condition, SP99 may be performed as a final procedure as follows:
1. Remove the unused RAM from a spare main board.
2. Remove the RAM from the main board of your machine and install the unused RAM.
3. Clear all memory by SP99.
4. Clean the drum area and optics section.
5. Make sky shot copies to reduce the toner density until SP55 shows Vsp between 0.40
volts and 0.70 volts.
6. Reinstall the original RAM on the main board of your machine.
NOTE: When the main switch is turned on after reinstalling RAM, the toner indicator
stays on. However, the machine automatically goes into the toner end
recovery and toner end condition is easily cleared.
7. Enter SP33 and set the data to "1".
8. Enter SP62 and increase the data by +2 from "SP Mode Factory Setting Data."
9. If the color development unit is installed, enter SP75 and set the data to "3".
10. Clear the VL correction by SP94.
11. Adjust the copy image by SP48 and SP56.
Страница 16
SUBJECT: Software modification DATE:
May 15, 1994
PAGE: 4 of 5
2. APS malfunction after using DF (Pigeon A only)
[Phenomenon]
For Pigeon A, the APS function is effective only when making a copy through DF.
However, when the original is placed on the exposure glass after completing a copy job
through DF, the APS function still stays engaged. The only way to clear the APS function
is to press the Clear Modes key.
[Cause]
Software problem
[Solution]
To cancel the APS function when the DF is open, the software has been changed.
With this change, the APS mode cannot be manually selected by pressing the Select
Paper Tray key. The APS mode is automatically selected only when an original is set on
the original table.
3. Drum counter problem
[Phenomenon]
The drum counter (SP69) does not display more than 65,000 copies.
NOTE: This problem does not affect the copy process control
[Cause]
Software problem
[Solution]
The software has been changed so that the drum counter displays until 999,999 copies.
Страница 17
SUBJECT: Software modification DATE:
May 15, 1994
PAGE: 5 of 5
4. Default for VL correction internal (SP61)
[Phenomenon]
Lighter copy image may appear on copies.
[Cause]
The VL correction is applied too early.
[Solution]
To reduce unnecessary call and match the environment where the machine is installed,
the default value for the VL correction interval (SP61) has been changed from "0" (+1/70H)
to "3" (+1/140H).
The cut-in serial numbers of the new ROM (P/N A1115107D) are as follows:
JAPAN Production RIF Production
Machine Code Cut-in Serial Number Machine Code Cut-in Serial Number
A110-10 2554050001
A110-15 0340500001
A110-17 A3474040385
A110-19 A3474040815
A110-22 2544040001 A110-22 2544640167
A110-26 3E30540001 A110-26 3E36540001
A110-27 A3474040877 A110-27 A3474640001
A110-29 A3474050665
A110-99 005405XXXX
A111-10 258405XXXX
A111-15 0740500001
A111-17 A3484040390
A111-19 A348405XXXX
A111-22 2574040001 A111-22 2574650001
A111-26 3E4054XXXX A111-26 3E46540001
A111-27 A3484040651 A111-27 A3484640231
A111-29 A3484050455
Страница 18
SUBJECT: High pitched noise from the dc power supply board DATE:Oct. 15, ’94
PAGE: 1 of 2
PREPARED BY: S. Orita FROM: 2nd Technical Support Section
CHECKED BY: S. Hamano
CLASSIFICATION: MODEL: Pigeon B (A111)
Action Required Revision of service manual
Troubleshooting Information only
Retrofit Information Other
– Phenomenon –
Coil (L101) on the dc power supply board makes a high pitched noise (Pigeon B only).
– Cause –
According to the tolerance of the switching regulator (IC101) on the dc power supply
board, the current from IC101 varies. If the current is lower than some threshold level, the
frequency of the switching regulator drops from 37.5KHz to 12.5KHz.
At this time, the coil (L101) starts to vibrate and makes a high pitched noise.
– Temporary countermeasure for the field machines with this problem –
To increase the current from IC101, we have registered the following countermeasure part
(150Ω, 10W resistor with harness) as a service part.
Part Number Description
A1119500 Noise Killer Harness
The installation procedure for this harness is as follows:
1. Remove the rear cover.
2. Remove a screw [A] on the rear cassette [E]
holder [B] from the rear side.
3. Install the noise killer harness [C] (1 screw).
4. Connect the connector [D] to CN127 on the
main board [E].
[A] NOTE: You cannot install this harness on a [D] [B] machine in which a key counter is used.
If this problem still occurs after this harness is
installed or the key counter is installed, install the
new dc power supply unit (P/N AZ230061) as the
final countermeasure.
[C]
Страница 19
SUBJECT: High pitched noise from the dc power supply board DATE:Oct. 15, ’94
PAGE: 2 of 2
– Final countermeasure for the production machines –
The circuit of the dc power supply board has been changed as follows:
Old P/N New P/N Description
AZ230039 AZ230061 DC Power Supply Board
1. Two 470Ω resistors (R115 and R116) have been added between the 24V line and GND.
2. C105 and C106 (capacitors) have been changed from 2200pF to 4700pF.
3. The width of the ground pattern has been increased.
Please refer to the MB No. 22 of the Pigeon for details (cut-in serial numbers, schematics,
etc.)
Страница 20
SUBJECT: Service Manual Correction DATE: Jan. 15, ’95
PAGE: 1 of 1
PREPARED BY: S. Hizen FROM: 2nd Technical Support Section
CHECKED BY: S. Hamano
CLASSIFICATION: MODEL:
Action Required Revision of service manual Pigeon A and B
Troubleshooting Information only
Retrofit Information Other
The procedure #4 in the service manual page 5-69 (6. 10:Corona Current Adjustment) is
not necessary for the Pigeon.
Delete procedure #4 "Disconnect CN123 on the main board" from Pigeon service manual.
Reason:
The Pigeon service manual was made based on the N220 series service manual.
The procedure is necessary for the N220 series because the N220 has a development unit
set sensor (CN123) and it is necessary to disconnect this sensor when the corona current
is adjusted.
The Pigeon does not have a development set sensor and the procedure #4 is not
necessary for these models.
Страница 21
SUBJECT: Software Modification DATE: July 31, ’95
PAGE: 1 of 2
PREPARED BY: N. Kaiya FROM: 2nd Technical Support Section
CHECKED BY:
CLASSIFICATION: MODEL:
Action Required Revision of service manual Pigeon A and B
Troubleshooting Information only (A110 / A111)
Retrofit Information Other
The Main ROM has been updated from A1115107D to A1115107E. The following
software problems have been corrected with the version E ROM.
1. APS mode is not selected after bypass feed
Symptom
When using the bypass feed and if the bypass feed table is closed right after the last
sheet of paper has been fed, the machine does not switch to APS mode.
Cause
Paper feed selection (default is APS) is not initialized when the bypass feed table is closed
before the end of a copy job.
Solution
The software has been corrected so that paper feed selection is initialized even if the
bypass feed table is closed before the end of a copy job.
2. The user code counter and total counter do not match
Symptom
The total number of copies in the user code counter and the total counter do not match
Cause
The number of sheets of paper fed is used for the user code counter while the number of
sheets of paper fed out is used for the total counter. If there are paper jams, the figures
from the two counters do not match.
Solution
The number of sheets of paper fed out will be used for both counters.
Страница 22
SUBJECT: Software Modification DATE: July 31, ’95
PAGE: 2 of 2
JAPAN Production RIF Production
Machine Code Cut-in Serial Number Machine Code Cut-in Serial Number
A110 – 10 2554100001
A110 – 15 0341000001
A110 – 17 A3474100001
A110 – 19 A3474100921
A110 – 22 2544100001
A110 – 26 3E31040001 A110 – 22 2544700001
A110 – 27 A3474101036 A110 – 26 3E37040001
A110 – 28 A3475030831 A110 – 27 A3474700039
A110 – 29 A3474091762
October production A110 – 99 onward
A111 – 10 2585070001
A111 – 15 0741000001
A111 – 17 A3484100001
November ’94 A111 – 19 production onward
A111 – 22 2574100001 A111 – 22 2574700001
A111 – 26 3E40150001 A111 – 26 3E47040001
A111 – 27 A3484100656 A111 – 27 A3484700293
A111 – 29 A3484100813
Страница 23
SUBJECT: Service Manual Correction DATE: April 30, ’95
PAGE: 1 of 1
PREPARED BY: S. Hizen FROM: 2nd Technical Support Section
CHECKED BY: M. Iwasa
CLASSIFICATION: MODEL:
Action Required Revision of service manual Pigeon
Troubleshooting Information only
Retrofit Information Other
User-Code 6 (U-6)
The U-6 is missing in the U-code section of the service manual page 6-24. Please add
the U-6 code to your service manual.
U-6:
At machine installation / drum replacement, the drum protection sleeve should be removed
and drum conditioning should be performed. If the sleeve is not removed, the ID sensor
output stays less than 1 volt during drum conditioning, resulting in U-6.
Solution:
Remove the drum protection sheet and turn the main switch off and on.
Страница 24
Model: Pigeon (USA Market only) Date: 30-Apr-98 No: 11
Subject: New Developer Type 411 Black Prepared by: M.Inohana
From: QAC Field Information Dept.
Classification: Troubleshooting Part information Action required
Mechanical Electrical Service manual revision
Paper path Transmit/receive Retrofit information
Other ( )
PURPOSES OF QUALITY IMPROVEMENT
Developer Type 410 Black sometimes allows a slight drop in image density over time
when used in the Pigeon copier.
CAUSE
In some cases, the Developer Type 410 Black cannot maintain the charge level high
enough for constant image density during the Pigeon’s copying process.
SOLUTION
Developer Type 411 Black has been newly developed to keep its charge level higher when
used in the Pigeon copier, and is now available for purchase in the market.
CAUTIONS
When using Developer Type 411 Black in the field, please be careful of the following.
1. The Developer Type 411 Black must be used with Toner Type 410. If the new
developer is used with other types of toner, toner scattering or abnormal image
problems may occur.
2. Reset the level of the photo-sensor voltage to [N] or [L]. This is necessary because
Developer Type 411 Black gives more electric charge to toner particles compared with
Type 410, so dirty background problems may occur if the photo-sensor voltage is set to
[H].
3. Developer Type 411 Black should only be used in the Pigeon copier. If it is used in
other models like the Ibis copier, this may result in dirty background.