Страница 1
SUBJECT: Cleaning Brush Drive Shaft DATE: Feb.15.’91
PAGE: 1 of 3
PREPARED BY: F. Noguchi FROM: Copier Technical Support Sec.
CHECKED BY: T. Ito Technical Support Department
CLASSIFICATION: MODEL:
Action Required Revision of service manual
Troubleshooting Information only F30/31
Retrofit Information Other
1. Symptom
Cleaning unit operates noisily and/or cleaning drive shaft locks.
2. Cause
A: When there is too much play between the cleaning brush groove and the drive shaft
(#A0073570), then the E-ring groove in the drive shaft becomes worn, causing no
unit drive.
B: If the cleaning brush holder is pushed by some unkown force , then an excessive
load is applied to the bushing area, causing brush to be locked.
3. Solution (on production line)
A: To ensure that the pin stays in the slot, the ∅2.5mm spring pin is being replaced
with a ∅2.5mm pin that is square shaped at one end, round at the other. The
square-shaped end increases the tolerance; the pin can move as far as 3.85mm
before disengaging from the slot.
Spring Pin ∅ 2.5mm
Old
Engagement Width 1 ∼ 2.6mm Cleaning Brush Drive shaft
Cleaning Brush
2.5mm square
New
Engagement With 2.25 ∼ 3.85
Страница 2
SUBJECT: Ceaning Brush Drive Shaft DATE: Feb.15.’91
PAGE: 2 of 3
B: To prevent the holder at the front side of the cleaning brush from coming off, the
positioning stud is secured with a cup nut that screws on to the end of pin.
Setting Pin
Screw Screw
(M4 x 6) (M4 x 6)
Cup Nut
Positioning Stud End Block Positioning Stud – Front End Block
Old New
To do this, the positioning stud (P/N AA143032) has been modified.
Note:Regarding the cut-in serial number, please see the MBs.
Modification A: We will issue an MB.
Modification B: MB No. 100 (issued on Nov.15.’90)
Страница 3
SUBJECT: Cleaning Brush Drive Shaft DATE: Feb.15.’91
PAGE: 3 of 3
4. Field countermeasures
A: Without replacing the drive shaft or installing the cup nut.
(1). Check to see if the drive shaft is worn or not. If so, replace it with a new one.
(2). Add the appropriate spacer (e.g. 1mm) to reduce the play within specifications
(0.2 – 0.6mm).
0.2 ∼ 0.6mm
Side Plate Spacer
(3). In order to securely tighten the holder[A], replace the screw[B] with a screw
and a flat washer (M4x8)
[B] [A]
B: Replacing the drive shaft and installing the cup nut.
Replace the following parts as a set order from SPC
A0079520 : Cleaning Brush Drive Shaft Set
(1) Cleaning Drive Shaft
(2) Positioning Stud – Front End Block 2
(3) Cup Nut
1 3
Страница 4
Technical Bulletin No. RTB-047
SUBJECT: Inverter Jam DATE: Feb. 15, ’91
PAGE: 1 of 4
PREPARED BY: M. Furusawa FROM: Copier Technical Support Sec.
CHECKED BY: T. Ito Technical Support Dept.
CLASSIFICATION: MODEL: F30/31
Action Required Revision of service manual
Troubleshooting Information only
Retrofit Information Other
1.SYMPTOM:
An "accordion" paper jam occurs at the inverter unit with the first sheet in duplex mode,
lighting the jam indicator "D" on the display panel.
Exit Relay Roller
Inverter
Pressuure Roller
Inverter return
Roller
The exact position where the leading edge of the paper stops is the third roller from the
front side of the guide plate.
[ Front ]
Inverter Return Roller
Страница 5
SUBJECT: Inverter Jam DATE: Feb. 15, ’91
PAGE: 2 of 4
When this occurs:
After about 100 copies have been made and the inside of the copier has heated up, this
paper jam may occur.
The occurrence ratio differs depending on the temperature, humidity,and paper type.
Paper jamming is most likely to occur under the following conditions:
* at low temperature
* at low humidity
* with certain brands of paper (ex. Sabre-X)
* when sideways A4 copies are made
2. CAUSE:
Open/Shut Guide Plate
Upper Guide Plate
Paper direction Paper direction
when guide plate when guide plate is
is not warped warped
A. The guide plate warps.
The open/shut guide plate warps and curves downward as shown as the result of heat
from the fusing unit.
Open / Shut Guide Plate
(molded plastic)
Страница 6
SUBJECT: Inverter Jam DATE: Feb. 15, ’91
PAGE: 3 of 4
B. The gap between the open/shut guide plate and the lower guide plate narrows.
Open/Shut Guide Plate
Ribs
Lower Guide Plate
The gap narrows in the center.
C. Paper passing through the guide plates has crease marks at the point where the gap
is narrow.
NOTE: This is also done
(intentionally) at the exit rollers to
create stiffness in the paper sheet.
D. This "stiff" paper proceeds strait ahead (due to its stiffness), and hits the inverter return
roller. Jams often occur at this point.
paper
Inverter Return Roller
If the gap between the plates is even, paper jams do not occur.
NOTE: This paper jam occurs only when the first sheet is fed in duplex mode because of
the short interval betweeen pages. The preceding sheet of paper prevents the
following sheet from hitting the inverter return roller.
Preceding paper
Following Paper
Inverter return Roller
Страница 7
SUBJECT: Inverter Jam DATE: Feb. 15, ’91
PAGE: 4 of 4
3. ACTION IN THE FIELD (Temporary Solution)
[ B ]
Place flat spacers [ A ] between the [ A ]
open/shut guide plate and the magnet.
This will raise the open/shut guide
plate [ B ].
Install the spacers. Line up the spacers with the arrows as shown.
Spacer : P/N A0458991 (Thickness = 0.5, Size = 10 X 80 mm)
Method of adhesion: Double sided tape
Open/Shut Guide Plate
SPACER (A0458991)
NOTE: This temporary solution has already been implemented from the November, ’90
production run. This countermeasure will be applied until a permanent solution is
found.
4. PERMANENT SOLUTION
The open/shut guide plate has been made thicker by 0.7mm at the place where the
spacers were stuck on.
a + t t = 0.7mm
NOTE: This permanent solution has been implemented from the September ’91
production run. (Refer to MB No. 119 issued on NOV. 30, ’91)
Страница 8
SUBJECT: Platinum Corona Wire DATE: Apr. 15, ’91
PAGE: 1 of 2
PREPARED BY: H. Kobayashi FROM:Copier Technical Support Section
CHECKED BY:
CLASSIFICATION: MODEL: F30/31
Action Required Revision of service manual
Troubleshooting Information only
Retrofit Information Other
The following platinum corona wires have been registered as service parts. The tungsten
corona wires are currently being installed on the assembly line, but they may be replaced
in the field with the platinum corona wires, if desired.
Platinum
Description Current Tungsten Corona P/N
corona P/N
# 52199540 Corona Wire (1 pc/set) # 52199101
# A0079540 Main Corona Wire (1 pc/set) # A0089001
# A0079541 PQC Corona Wire (1 pc/set) # A0079002
# A0079542 Transfer Corona Wire (1 pc/set) # A0079003
The platinum and the tungsten corona wires are fairly similar in performance and handling;
however, there are the following differences:
Point 1
During the copy cycle, less foreign matter (toner, dust, gas) will build up on the surface of
a platinum corona wire than on a tungsten wire. Consequently, platinum corona wires do
not need to be cleaned as often to maintain copy quality. This is true for both these
platinum corona wires and the third vendor’s platinum corona wires.
Point 2
Negative charges cause portions of the surface of a platinum corona wire to break off,
affecting the copy image and requiring replacement of the wire. A platinum wire cannot be
used as a negative charge corona. (A tungsten wire can be used as a negative charge
corona wire.) This is true for both these platinum corona wires and the third vendor’s
platinum corona wires.
Страница 9
SUBJECT: Platinum Corona Wire DATE: Apr. 15, ’91
PAGE: 2 of 2
–When to install the platinum corona wires-
The platinum corona wires do not have to be cleaned as often as the tungsten wires
(point 1). For this reason, the platinum corona wires are most suitable in cases where a
machine is installed in a relatively inaccessible location (far from a service center) and
service calls are difficult to make.
The platinum wires can be installed in the field on the following models:
Model Main Transfer PQC PCC Separation PTC
F20 # 52199540 # 52199540 # 52199540 Negative Negative Negative
F21 charge. charge. charge.
F22 Do not use. Do not use. Do not use.
F30 # A0079540 # A0079542 # A0079541 Negative Negative Not used.
F31 charge. charge.
F33 Do not use. Do not use.
F34
F40
Note 1
When installing the platinum corona wires, please take the following actions:
1. Clean the corona casings, end blocks, and new platinum wires with damp cloth.
2. Confirm VSG.
Note 2
# A0079540 can also be used as the F90 main corona wire.
Страница 10
SUBJECT: Installation Procedure change DATE: May 31,1991
PAGE: 1 of 2
PREPARED BY: F. Noguchi FROM: Copier Technical Support Section
CHECKED BY: T. Ito
CLASSIFICATION: MODEL:
Action Required Revision of service manual
Troubleshooting Information only F 31
Retrofit Information Other
The following shipping retainer has been changed:
a) The location of the shipping tape has been changed.
b) A cushion has been added.
c) The retainer of the lower left side has been eliminated.
The installation procedure has been changed as follows:
OLD
[A]
[C]
[B]
[C]
[D]
[E]
10. Remove the lower right cover [A] (4 screws) and the lower left cover [B] (2 screws),
then remove two retainers [C] (4 screws each).
11. Pull the drawer [D] all the way out, and remove the strips of tape [E].
12. Reset the drawer and reinstall the lower right and lower left covers.
Страница 11
SUBJECT:Installation Procedure change DATE: May 31,1991
PAGE: 2 of 2
NEW
[A] [B]
[D]
[C] [E]
10. Remove the lower left cover[A] (2 screws), then remove the retainer [B] (4 screws).
11. Slide out the paper feed unit [C], then remove all strips of filament tape [D] and the
cushion [E].
12. Put the paper feed unit back and reinstall the lower left cover.
This modification is applied from the 1991 May production run.
Страница 12
SUBJECT: Erratic operation DATE: 15 July ’91
PAGE: 1 of 2
PREPARED BY: F. Noguchi From: Copier Technical Support Section
CHECKED BY: T. Ito Technical Support Department
CLASSIFICATION: MODEL: F30/31
Action Required Revision of service manual
Troubleshooting Information only
Retrofit Information Other
1. Symptom
During copy operation, the machine sometimes shows some of the following symptoms:
(1) Paper feeds through continuously
(2) Different SC code is displayed
(3) RAM data is cleared
(4) Erratic display is shown
(5) Language in the message display is changed
(6) others
The above also happens during free run and drum conditioning.
2. Cause and objective machines
Some scanner motors(AX060023) may generate high electrical noise, causing the
above symptom.
This motor has been used in machines with these serial numbers and onwards:
Japan production
A007 -17 from 4000218765
-19 from ‘90 Feb. production
others from ‘90 Mar. production
A019 -11 from ‘90 Mar. production
-15 from ‘90 Mar. production
-16 from ‘90 Mar. production
-25 from ‘90 Mar. production Harness
others from ‘90 Apr. production
REI production
A007 all from first production
A019 all from first production
3. Solution
For the problem machines, install the ferrite core
harness(A0078999) on the 30V motor drive lines
as shown. This will reduce the peak noise level.
Страница 13
SUBJECT: Erratic operation DATE: 15 Oct. ’91
PAGE: 2 of 2
4. Cut-in serial number for the factory modification:
Japan production
A007-16 : 301070002 ∼ 007, 009, 013
and from ’91 Aug. production
A007-17 : from ’91 Sep. production (no production in Aug.)
A007-19 : 4010724339 ∼ 348
and from ’91 Sep. production (no production in Aug.)
A007-25 : 301070099 ∼ 105, 107, 108, 115, 116, 119 ∼ 123
and from 301070125
A007-26 : from ’91 Sep. production (no production in Aug.)
A007-27 : 4010724376, 388, 390, 428, 438, 444, 445, 447, 449, 456
and from 4010724464
A007-29 : from 4010724490
A007-51 : from ’91 Oct. production (no production in Aug. and Sep.)
A007-56 : from ’91 Oct. production (no production in Aug. and Sep.)
A007-59 : from 4110702291
A007-65 : from ’91 Oct. production (no production in Aug. and Sep.)
A007-66 : from ’91 Oct. production (no production in Aug. and Sep.)
A007-67 : from 4110702301
A007-69 : from ’91 Oct. production (no production in Aug. and Sep.)
A007-76 : from 3510710031
A019-11 : from ’91 Sep. production (no production in Aug.)
A019-15 : from ’91 Sep. production (no production in Aug.)
A019-16 : from ’91 Sep. production (no production in Aug.)
A019-25 : from ’91 Sep. production (no production in Aug.)
A019-26 : from ’91 Sep. production (no production in Aug.)
A019-27 : 2021070002 ∼ 044, 046 ∼ 121, 124, 125, 130, 131, 135 ∼ 146, 148 ∼ 150
and from ’91 Aug. production
A019-29 : from ’91 Sep. production (no production in Aug.)
REI production
A007-06 : from 4014901071
A019-06 : from ’91 Oct. production (no production in Aug. and Sep.)
A019-08 : from 9415000926